联合循环电厂备用停机润滑油冷却器风扇的优化设计

Raihan Raihan
{"title":"联合循环电厂备用停机润滑油冷却器风扇的优化设计","authors":"Raihan Raihan","doi":"10.33322/energi.v15i1.1944","DOIUrl":null,"url":null,"abstract":"Lube oil cooler fan at Combine Cycle Power Plant (CCPP) Block 1-2 PT. PLN Indonesia Power Priok is used as a heat exchanger to reduce the temperature of the lubricant that has passed through the system so that it can return through the system at a lower temperature. CCPP Block 1-2 often experience Start-Shutdown units due to requests from the PLN load regulator, therefore the lube oil cooler fan often continues to operate even though the lubricant temperature is low during the Shutdown (RS). The lube oil cooler fan optimization program is an activity to turn off one fan during the reverse shutdown unit and turn off all the fans manually by the operator when the lubricant temperature is below 42oC and then recorded for documentation. This activity is contained in the Standard Operating Procedure regarding energy saving during RS Gas Turbines. With the existence of an optimization program for operating patterns by turning off the lube oil cooler fan, it is hoped that it will be able to reduce power, with the target of reducing electric power consumption by 40,000 KWh per year. This program can save 165,454.34 kWh of power in 2020, or the equivalent of 595.64 GJ, and in 2021 it can save 101,468.40 kWh of energy, or the equivalent of 365.29 GJ.","PeriodicalId":166066,"journal":{"name":"ENERGI & KELISTRIKAN","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimization of Lube Oil Cooler Fan at Reserve Shutdown Combined Cycle Power Plant Priok\",\"authors\":\"Raihan Raihan\",\"doi\":\"10.33322/energi.v15i1.1944\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lube oil cooler fan at Combine Cycle Power Plant (CCPP) Block 1-2 PT. PLN Indonesia Power Priok is used as a heat exchanger to reduce the temperature of the lubricant that has passed through the system so that it can return through the system at a lower temperature. CCPP Block 1-2 often experience Start-Shutdown units due to requests from the PLN load regulator, therefore the lube oil cooler fan often continues to operate even though the lubricant temperature is low during the Shutdown (RS). The lube oil cooler fan optimization program is an activity to turn off one fan during the reverse shutdown unit and turn off all the fans manually by the operator when the lubricant temperature is below 42oC and then recorded for documentation. This activity is contained in the Standard Operating Procedure regarding energy saving during RS Gas Turbines. With the existence of an optimization program for operating patterns by turning off the lube oil cooler fan, it is hoped that it will be able to reduce power, with the target of reducing electric power consumption by 40,000 KWh per year. This program can save 165,454.34 kWh of power in 2020, or the equivalent of 595.64 GJ, and in 2021 it can save 101,468.40 kWh of energy, or the equivalent of 365.29 GJ.\",\"PeriodicalId\":166066,\"journal\":{\"name\":\"ENERGI & KELISTRIKAN\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ENERGI & KELISTRIKAN\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33322/energi.v15i1.1944\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ENERGI & KELISTRIKAN","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33322/energi.v15i1.1944","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

联合循环电厂(CCPP) Block 1-2 PT. PLN Indonesia Power Priok的润滑油冷却器风扇被用作热交换器,以降低通过系统的润滑剂的温度,使其能够以较低的温度返回系统。由于PLN负载调节器的要求,CCPP Block 1-2经常经历启停单元,因此即使在停机(RS)期间润滑油温度较低,润滑油冷却器风扇也经常继续运行。润滑油冷却器风扇优化程序是一项活动,在反向停机装置期间关闭一个风扇,当润滑油温度低于42℃时,由操作员手动关闭所有风扇,然后记录为文件。这项活动包含在关于RS燃气轮机节能的标准操作程序中。通过关闭润滑油冷却器风扇的运行模式优化程序的存在,希望能够降低功率,目标是每年减少40,000千瓦时的电力消耗。该方案2020年可节电165,454.34 kWh,折合595.64 GJ, 2021年可节电101,468.40 kWh,折合365.29 GJ。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimization of Lube Oil Cooler Fan at Reserve Shutdown Combined Cycle Power Plant Priok
Lube oil cooler fan at Combine Cycle Power Plant (CCPP) Block 1-2 PT. PLN Indonesia Power Priok is used as a heat exchanger to reduce the temperature of the lubricant that has passed through the system so that it can return through the system at a lower temperature. CCPP Block 1-2 often experience Start-Shutdown units due to requests from the PLN load regulator, therefore the lube oil cooler fan often continues to operate even though the lubricant temperature is low during the Shutdown (RS). The lube oil cooler fan optimization program is an activity to turn off one fan during the reverse shutdown unit and turn off all the fans manually by the operator when the lubricant temperature is below 42oC and then recorded for documentation. This activity is contained in the Standard Operating Procedure regarding energy saving during RS Gas Turbines. With the existence of an optimization program for operating patterns by turning off the lube oil cooler fan, it is hoped that it will be able to reduce power, with the target of reducing electric power consumption by 40,000 KWh per year. This program can save 165,454.34 kWh of power in 2020, or the equivalent of 595.64 GJ, and in 2021 it can save 101,468.40 kWh of energy, or the equivalent of 365.29 GJ.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimization of Lube Oil Cooler Fan at Reserve Shutdown Combined Cycle Power Plant Priok Pengaruh SVL Pada Metallic Sheat Underground Cable 150 kV Terhadap Transient Switching Capasitor Bank PLTU FTP 2 Lombok 2x50 MW Perancangan Sistem Monitoring Pada Pemilah Sampah Otomatis Berbasis Internet of Things Menggunakan Aplikasi Blynk Analisis Rancang Bangun Implementasi SCADA System Untuk Peningkatan Performa Mesin Produksi Pada Proses Washing Component Manufacture Engine Assembling Analisis Sistem Pencahayaan Pada Lantai 3 Gedung Kuliah Umum Institut Teknologi Sumatera
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1