Nawoda Hewage, Lakshani Y. Dassanayaka, Deepthi Inoka Uluwaduge
{"title":"氟化钠试管与普通试管用于体外血糖分析","authors":"Nawoda Hewage, Lakshani Y. Dassanayaka, Deepthi Inoka Uluwaduge","doi":"10.4038/CJMS.V55I2.4936","DOIUrl":null,"url":null,"abstract":"Background: In terms of diagnosis and management of diabetes mellitus, the most commonly requested core biochemistry test worldwide is measurement of glucose in blood. Despite the wide use of sodium fluoride (NaF) as the specimen preservative, its use has been critically questioned. Objective: This study investigated the stability of glucose in blood obtained into plain tubes in comparison with sodium fluoride/potassium oxalate (NaF/K2C2O4) tubes in a routine laboratory setup. Methods: Sixty one pairs of blood specimens were collected into plain tubes and NaF/K2C2O4 tubes. Following separation of plasma (NaF/K2C2O4 tubes) and serum (plain tubes), glucose concentration was measured. Five determinants were obtained; the baseline glucose value, glucose concentrations at one, two, four and six hours after collection of blood into NaF/K2C2O4 or plain tubes. Results: A high rate of haemolysis was observed in NaF/K2C2O4 tubes when compared with that of plain tubes (11% vs. 4%). No effect of tube type on serum/plasma glucose concentration (p>.05) was noted until two hours post collection. A significant reduction (p Conclusion: Plain tubes are a better option for collection and processing blood in measurement of glucose if the separation is achieved within a reasonable time period.","PeriodicalId":253405,"journal":{"name":"Ceylon Journal of Medical Science","volume":"82 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sodium Fluoride tubes versus plain tubes for In vitro blood glucose analysis\",\"authors\":\"Nawoda Hewage, Lakshani Y. Dassanayaka, Deepthi Inoka Uluwaduge\",\"doi\":\"10.4038/CJMS.V55I2.4936\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: In terms of diagnosis and management of diabetes mellitus, the most commonly requested core biochemistry test worldwide is measurement of glucose in blood. Despite the wide use of sodium fluoride (NaF) as the specimen preservative, its use has been critically questioned. Objective: This study investigated the stability of glucose in blood obtained into plain tubes in comparison with sodium fluoride/potassium oxalate (NaF/K2C2O4) tubes in a routine laboratory setup. Methods: Sixty one pairs of blood specimens were collected into plain tubes and NaF/K2C2O4 tubes. Following separation of plasma (NaF/K2C2O4 tubes) and serum (plain tubes), glucose concentration was measured. Five determinants were obtained; the baseline glucose value, glucose concentrations at one, two, four and six hours after collection of blood into NaF/K2C2O4 or plain tubes. Results: A high rate of haemolysis was observed in NaF/K2C2O4 tubes when compared with that of plain tubes (11% vs. 4%). No effect of tube type on serum/plasma glucose concentration (p>.05) was noted until two hours post collection. A significant reduction (p Conclusion: Plain tubes are a better option for collection and processing blood in measurement of glucose if the separation is achieved within a reasonable time period.\",\"PeriodicalId\":253405,\"journal\":{\"name\":\"Ceylon Journal of Medical Science\",\"volume\":\"82 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ceylon Journal of Medical Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4038/CJMS.V55I2.4936\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceylon Journal of Medical Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4038/CJMS.V55I2.4936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
背景:在糖尿病的诊断和治疗方面,世界范围内最常用的核心生化检测是血葡萄糖的测定。尽管氟化钠(NaF)作为标本防腐剂被广泛使用,但它的使用受到了严格的质疑。目的:研究普通试管与氟化钠/草酸钾(NaF/K2C2O4)试管的血糖稳定性。方法:采集61对血液标本,分别分为普通管和NaF/K2C2O4管。血浆(NaF/K2C2O4管)和血清(普通管)分离后,测定葡萄糖浓度。得到五个决定因素;NaF/K2C2O4或普通管采血后1、2、4和6小时的基线血糖值和葡萄糖浓度。结果:NaF/K2C2O4管溶血率高于普通管(11% vs. 4%)。试管类型对血清/血浆葡萄糖浓度没有影响(p> 0.05),直到采集后2小时。结论:如果在合理的时间内实现分离,平管是采集和处理血液中葡萄糖测量的更好选择。
Sodium Fluoride tubes versus plain tubes for In vitro blood glucose analysis
Background: In terms of diagnosis and management of diabetes mellitus, the most commonly requested core biochemistry test worldwide is measurement of glucose in blood. Despite the wide use of sodium fluoride (NaF) as the specimen preservative, its use has been critically questioned. Objective: This study investigated the stability of glucose in blood obtained into plain tubes in comparison with sodium fluoride/potassium oxalate (NaF/K2C2O4) tubes in a routine laboratory setup. Methods: Sixty one pairs of blood specimens were collected into plain tubes and NaF/K2C2O4 tubes. Following separation of plasma (NaF/K2C2O4 tubes) and serum (plain tubes), glucose concentration was measured. Five determinants were obtained; the baseline glucose value, glucose concentrations at one, two, four and six hours after collection of blood into NaF/K2C2O4 or plain tubes. Results: A high rate of haemolysis was observed in NaF/K2C2O4 tubes when compared with that of plain tubes (11% vs. 4%). No effect of tube type on serum/plasma glucose concentration (p>.05) was noted until two hours post collection. A significant reduction (p Conclusion: Plain tubes are a better option for collection and processing blood in measurement of glucose if the separation is achieved within a reasonable time period.