PET研究中随机校正的迭代图像重建

SPIE Proceedings Pub Date : 2000-06-06 DOI:10.1117/12.387629
Jyh-Cheng Chen, Ren-Shyan Liu, K. Tu, Henry Horng-Shing Lu, Tai-Been Chen, K. Chou
{"title":"PET研究中随机校正的迭代图像重建","authors":"Jyh-Cheng Chen, Ren-Shyan Liu, K. Tu, Henry Horng-Shing Lu, Tai-Been Chen, K. Chou","doi":"10.1117/12.387629","DOIUrl":null,"url":null,"abstract":"A maximum likelihood-expectation maximization (ML-EM) reconstruction algorithm has been developed that allows random coincidence correction for the phantom we used and the reconstructed images are better than those obtained by convolution backprojection (CBP) for positron emission tomography (PET) studies in terms of spatial resolution, image artifacts and noise. With our algorithm reconstruct the true coincidence events and random coincidence events were reconstructed separately. We also calculated the random ratio from the measured projection data (singles) using line and cylindrical phantoms, respectively. From cylindrical phantom experiments, the random event ratio was 41.8% to 49.1% in each ring. These results are close to the ratios obtained from geometric calculation, which range from 45.0% to 49.5%. The random ratios and the patterns of random events provide insightful information for random correction. This information is particularly valuable when the delay window correction is not available as in the case of our PET system.","PeriodicalId":348386,"journal":{"name":"SPIE Proceedings","volume":"96 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-06-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Iterative image reconstruction with random correction for PET studies\",\"authors\":\"Jyh-Cheng Chen, Ren-Shyan Liu, K. Tu, Henry Horng-Shing Lu, Tai-Been Chen, K. Chou\",\"doi\":\"10.1117/12.387629\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A maximum likelihood-expectation maximization (ML-EM) reconstruction algorithm has been developed that allows random coincidence correction for the phantom we used and the reconstructed images are better than those obtained by convolution backprojection (CBP) for positron emission tomography (PET) studies in terms of spatial resolution, image artifacts and noise. With our algorithm reconstruct the true coincidence events and random coincidence events were reconstructed separately. We also calculated the random ratio from the measured projection data (singles) using line and cylindrical phantoms, respectively. From cylindrical phantom experiments, the random event ratio was 41.8% to 49.1% in each ring. These results are close to the ratios obtained from geometric calculation, which range from 45.0% to 49.5%. The random ratios and the patterns of random events provide insightful information for random correction. This information is particularly valuable when the delay window correction is not available as in the case of our PET system.\",\"PeriodicalId\":348386,\"journal\":{\"name\":\"SPIE Proceedings\",\"volume\":\"96 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-06-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SPIE Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.387629\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPIE Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.387629","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

一种最大似然期望最大化(ML-EM)重建算法允许对我们使用的幻影进行随机重合校正,并且在空间分辨率,图像伪影和噪声方面,重建图像优于卷积反投影(CBP)获得的正电子发射断层扫描(PET)研究。该算法分别对真实巧合事件和随机巧合事件进行了重构。我们还从测量的投影数据(单个)中分别使用线形和圆柱形幻影计算了随机比率。圆柱形幻像实验中,每个环的随机事件比为41.8% ~ 49.1%。这些结果与几何计算的比率接近,其范围为45.0% ~ 49.5%。随机比率和随机事件的模式为随机校正提供了有见地的信息。在我们的PET系统中,当延迟窗口校正不可用时,此信息特别有价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Iterative image reconstruction with random correction for PET studies
A maximum likelihood-expectation maximization (ML-EM) reconstruction algorithm has been developed that allows random coincidence correction for the phantom we used and the reconstructed images are better than those obtained by convolution backprojection (CBP) for positron emission tomography (PET) studies in terms of spatial resolution, image artifacts and noise. With our algorithm reconstruct the true coincidence events and random coincidence events were reconstructed separately. We also calculated the random ratio from the measured projection data (singles) using line and cylindrical phantoms, respectively. From cylindrical phantom experiments, the random event ratio was 41.8% to 49.1% in each ring. These results are close to the ratios obtained from geometric calculation, which range from 45.0% to 49.5%. The random ratios and the patterns of random events provide insightful information for random correction. This information is particularly valuable when the delay window correction is not available as in the case of our PET system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Front Matter: Volume 8264 Iterative image reconstruction with random correction for PET studies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1