并网逆变器的抗孤岛建模

Yingqi Zhang
{"title":"并网逆变器的抗孤岛建模","authors":"Yingqi Zhang","doi":"10.1109/PEAC.2014.7037933","DOIUrl":null,"url":null,"abstract":"For grid-tied inverters, islanding occurs when the grid is disconnected but the inverters are still energizing the local loads. When the inverter output active and reactive power match the local loads, the inverter output voltage and frequency will keep the same values as before. Islanding poses a hazard to maintenance workers and equipment. To detect islanding, a disturbance signal is usually added to the reference of the inverter output real power or reactive power with positive feedback manner. If the inverter output voltage or inverter output frequency is driven outside of the normal range, islanding is detected and the inverter will be de-energized. A parallel RLC load is widely used to verify effectiveness of anti-islanding detection. In this paper, transfer functions of anti-islanding loop gain are derived. These transfer functions are used to design anti-islanding control loop. Time domain simulation results are also included.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Anti-islanding modeling of grid-tied inverters\",\"authors\":\"Yingqi Zhang\",\"doi\":\"10.1109/PEAC.2014.7037933\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For grid-tied inverters, islanding occurs when the grid is disconnected but the inverters are still energizing the local loads. When the inverter output active and reactive power match the local loads, the inverter output voltage and frequency will keep the same values as before. Islanding poses a hazard to maintenance workers and equipment. To detect islanding, a disturbance signal is usually added to the reference of the inverter output real power or reactive power with positive feedback manner. If the inverter output voltage or inverter output frequency is driven outside of the normal range, islanding is detected and the inverter will be de-energized. A parallel RLC load is widely used to verify effectiveness of anti-islanding detection. In this paper, transfer functions of anti-islanding loop gain are derived. These transfer functions are used to design anti-islanding control loop. Time domain simulation results are also included.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7037933\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7037933","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对于并网逆变器,当电网断开但逆变器仍在为本地负载供电时,就会发生孤岛。当逆变器输出有功功率和无功功率与本地负载匹配时,逆变器输出电压和频率保持不变。孤岛对维修人员和设备构成危险。为了检测孤岛,通常以正反馈的方式在逆变器输出实功率或无功功率的基准上增加一个干扰信号。如果变频器输出电压或变频器输出频率被驱动超出正常范围,检测到孤岛,逆变器将断电。并联RLC负载被广泛用于验证抗孤岛检测的有效性。本文推导了抗孤岛回路增益的传递函数。利用这些传递函数设计了抗孤岛控制回路。最后给出了时域仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Anti-islanding modeling of grid-tied inverters
For grid-tied inverters, islanding occurs when the grid is disconnected but the inverters are still energizing the local loads. When the inverter output active and reactive power match the local loads, the inverter output voltage and frequency will keep the same values as before. Islanding poses a hazard to maintenance workers and equipment. To detect islanding, a disturbance signal is usually added to the reference of the inverter output real power or reactive power with positive feedback manner. If the inverter output voltage or inverter output frequency is driven outside of the normal range, islanding is detected and the inverter will be de-energized. A parallel RLC load is widely used to verify effectiveness of anti-islanding detection. In this paper, transfer functions of anti-islanding loop gain are derived. These transfer functions are used to design anti-islanding control loop. Time domain simulation results are also included.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonic stability assessment for multi-paralleled, grid-connected inverters An up-to-date review of large marine tidal current turbine technologies Optimal control for a self-reacting point absorber: A one-body equivalent model approach Comparison of direct-drive PM generators for tidal turbines Ocean wave energy extraction: Up-to-date technologies review and evaluation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1