{"title":"在直角坐标下交流功率流的线性近似","authors":"S. Dhople, Swaroop S. Guggilam, Y. Chen","doi":"10.1109/ALLERTON.2015.7447006","DOIUrl":null,"url":null,"abstract":"This paper explores solutions to linearized power-flow equations with bus-voltage phasors represented in rectangular coordinates. The key idea is to solve for complex-valued perturbations around a nominal voltage profile from a set of linear equations that are obtained by neglecting quadratic terms in the original nonlinear power-flow equations. We prove that for lossless networks, the voltage profile where the real part of the perturbation is suppressed satisfies active-power balance in the original nonlinear system of equations. This result motivates the development of approximate solutions that improve over conventional DC power-flow approximations, since the model includes ZIP loads. For distribution networks that only contain ZIP loads in addition to a slack bus, we recover a linear relationship between the approximate voltage profile and the constant-current component of the loads and the nodal active-and reactive-power injections.","PeriodicalId":112948,"journal":{"name":"2015 53rd Annual Allerton Conference on Communication, Control, and Computing (Allerton)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"88","resultStr":"{\"title\":\"Linear approximations to AC power flow in rectangular coordinates\",\"authors\":\"S. Dhople, Swaroop S. Guggilam, Y. Chen\",\"doi\":\"10.1109/ALLERTON.2015.7447006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper explores solutions to linearized power-flow equations with bus-voltage phasors represented in rectangular coordinates. The key idea is to solve for complex-valued perturbations around a nominal voltage profile from a set of linear equations that are obtained by neglecting quadratic terms in the original nonlinear power-flow equations. We prove that for lossless networks, the voltage profile where the real part of the perturbation is suppressed satisfies active-power balance in the original nonlinear system of equations. This result motivates the development of approximate solutions that improve over conventional DC power-flow approximations, since the model includes ZIP loads. For distribution networks that only contain ZIP loads in addition to a slack bus, we recover a linear relationship between the approximate voltage profile and the constant-current component of the loads and the nodal active-and reactive-power injections.\",\"PeriodicalId\":112948,\"journal\":{\"name\":\"2015 53rd Annual Allerton Conference on Communication, Control, and Computing (Allerton)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"88\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 53rd Annual Allerton Conference on Communication, Control, and Computing (Allerton)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ALLERTON.2015.7447006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 53rd Annual Allerton Conference on Communication, Control, and Computing (Allerton)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ALLERTON.2015.7447006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Linear approximations to AC power flow in rectangular coordinates
This paper explores solutions to linearized power-flow equations with bus-voltage phasors represented in rectangular coordinates. The key idea is to solve for complex-valued perturbations around a nominal voltage profile from a set of linear equations that are obtained by neglecting quadratic terms in the original nonlinear power-flow equations. We prove that for lossless networks, the voltage profile where the real part of the perturbation is suppressed satisfies active-power balance in the original nonlinear system of equations. This result motivates the development of approximate solutions that improve over conventional DC power-flow approximations, since the model includes ZIP loads. For distribution networks that only contain ZIP loads in addition to a slack bus, we recover a linear relationship between the approximate voltage profile and the constant-current component of the loads and the nodal active-and reactive-power injections.