{"title":"基于CFX数值模拟的直井测斜仪脉冲冲蚀机理研究","authors":"Jinsong Huang, Yu-Qing Cai, Wu-chun Feng, Qin Li, Xin Wang","doi":"10.1145/3558819.3565195","DOIUrl":null,"url":null,"abstract":"In the application of vertical well inclinometer, the erosion wear of pulser under various working conditions such as high displacement is the main factor leading to its failure. In this paper, based on the analysis of erosion factors and theoretical erosion rate, SolidWorks is used to restore the pulse structure with the same material and the same size. DPM multiphase flow model in Fluent and CFX numerical simulation is used to simulate the fluid/particle movement state and distribution law of the pulse under the downhole operation state. From the velocity, pressure, turbulence parameters, particle mass concentration and other body parts for key erosion, erosion mechanism and analysis, main show is to fluid cluster after local turbulence caused by the phenomenon, the upper fluid blocked reflection and original fluid phenomenon of turbulence in the collision, water hammer effect of instantaneous high pressure effect, local vortex caused by uneven pressure, The flow regime changes caused by Karman vortex street effect, the collision process caused by the accumulation and aggregation of particles, and the impact process caused by the fluid transport particles on the wall.","PeriodicalId":373484,"journal":{"name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Study on the Pulser Erosion Mechanism of Vertical Well Inclinometer through CFX Numerical Simulation\",\"authors\":\"Jinsong Huang, Yu-Qing Cai, Wu-chun Feng, Qin Li, Xin Wang\",\"doi\":\"10.1145/3558819.3565195\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the application of vertical well inclinometer, the erosion wear of pulser under various working conditions such as high displacement is the main factor leading to its failure. In this paper, based on the analysis of erosion factors and theoretical erosion rate, SolidWorks is used to restore the pulse structure with the same material and the same size. DPM multiphase flow model in Fluent and CFX numerical simulation is used to simulate the fluid/particle movement state and distribution law of the pulse under the downhole operation state. From the velocity, pressure, turbulence parameters, particle mass concentration and other body parts for key erosion, erosion mechanism and analysis, main show is to fluid cluster after local turbulence caused by the phenomenon, the upper fluid blocked reflection and original fluid phenomenon of turbulence in the collision, water hammer effect of instantaneous high pressure effect, local vortex caused by uneven pressure, The flow regime changes caused by Karman vortex street effect, the collision process caused by the accumulation and aggregation of particles, and the impact process caused by the fluid transport particles on the wall.\",\"PeriodicalId\":373484,\"journal\":{\"name\":\"Proceedings of the 7th International Conference on Cyber Security and Information Engineering\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 7th International Conference on Cyber Security and Information Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3558819.3565195\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3558819.3565195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在直井倾角仪的应用中,脉冲器在大排量等各种工况下的冲蚀磨损是导致其失效的主要因素。本文在分析侵蚀因素和理论侵蚀速率的基础上,利用SolidWorks对相同材料、相同尺寸的脉冲结构进行恢复。利用Fluent中的DPM多相流模型和CFX数值模拟,模拟了井下工作状态下流体/颗粒的运动状态和脉冲分布规律。从速度、压力、湍流参数、颗粒质量浓度等对主体部位的关键侵蚀、侵蚀机理进行分析,主要表现为流体聚集后引起的局部湍流现象、上部流体阻塞反射与原始流体的湍流现象在碰撞、水锤效应瞬时高压效应、局部涡旋造成的压力不均匀、流态变化引起的卡门涡街效应等;由颗粒堆积聚集引起的碰撞过程,以及流体输运颗粒对壁面造成的冲击过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on the Pulser Erosion Mechanism of Vertical Well Inclinometer through CFX Numerical Simulation
In the application of vertical well inclinometer, the erosion wear of pulser under various working conditions such as high displacement is the main factor leading to its failure. In this paper, based on the analysis of erosion factors and theoretical erosion rate, SolidWorks is used to restore the pulse structure with the same material and the same size. DPM multiphase flow model in Fluent and CFX numerical simulation is used to simulate the fluid/particle movement state and distribution law of the pulse under the downhole operation state. From the velocity, pressure, turbulence parameters, particle mass concentration and other body parts for key erosion, erosion mechanism and analysis, main show is to fluid cluster after local turbulence caused by the phenomenon, the upper fluid blocked reflection and original fluid phenomenon of turbulence in the collision, water hammer effect of instantaneous high pressure effect, local vortex caused by uneven pressure, The flow regime changes caused by Karman vortex street effect, the collision process caused by the accumulation and aggregation of particles, and the impact process caused by the fluid transport particles on the wall.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development and Application of Portable Multi-Function Power Distribution Emergency Repair Standardized Equipment Research on Automatic Self-healing Control of Intelligent Feeder based on Multi-Agent Algorithm Research and implementation of IP address management in medium and large-scale local area networks Application of Compressive Sensing Technology and Image Processing in Space Exploration House Price Prediction Model Using Bridge Memristors Recurrent Neural Network
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1