{"title":"多运行场景下电力系统中pmu的放置","authors":"Lei Huang, Jian Xu, Yuanzhan Sun, Wenzhong Gao, Xiaoming Li, Jianxun Dong, Chengzhu Qi","doi":"10.1109/NAPS.2013.6666836","DOIUrl":null,"url":null,"abstract":"This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding scenario. The optimization objective of proposed model is to minimize the number of installed PMUs and then maximize the measurement redundancy. To take advantage of the power network topology, the effect of zero-injection bus is incorporated into the model. Furthermore, additional observability constraints for single PMU or line loss are also derived. At last, test results on IEEE 118-bus system are presented to demonstrate the effectiveness of the proposed method.","PeriodicalId":421943,"journal":{"name":"2013 North American Power Symposium (NAPS)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Placement of PMUs in power systems with multiple operation scenarios\",\"authors\":\"Lei Huang, Jian Xu, Yuanzhan Sun, Wenzhong Gao, Xiaoming Li, Jianxun Dong, Chengzhu Qi\",\"doi\":\"10.1109/NAPS.2013.6666836\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding scenario. The optimization objective of proposed model is to minimize the number of installed PMUs and then maximize the measurement redundancy. To take advantage of the power network topology, the effect of zero-injection bus is incorporated into the model. Furthermore, additional observability constraints for single PMU or line loss are also derived. At last, test results on IEEE 118-bus system are presented to demonstrate the effectiveness of the proposed method.\",\"PeriodicalId\":421943,\"journal\":{\"name\":\"2013 North American Power Symposium (NAPS)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-11-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 North American Power Symposium (NAPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NAPS.2013.6666836\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2013.6666836","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Placement of PMUs in power systems with multiple operation scenarios
This paper proposes an optimal PMU placement (OPP) model to make power system observable for normal operation condition as well as controlled islanding scenario. The optimization objective of proposed model is to minimize the number of installed PMUs and then maximize the measurement redundancy. To take advantage of the power network topology, the effect of zero-injection bus is incorporated into the model. Furthermore, additional observability constraints for single PMU or line loss are also derived. At last, test results on IEEE 118-bus system are presented to demonstrate the effectiveness of the proposed method.