{"title":"湖泊水体扩散衰减系数谱的模式计算","authors":"B. Paavel, H. Arst, A. Reinart, A. Herlevi","doi":"10.3176/biol.ecol.2006.1.05","DOIUrl":null,"url":null,"abstract":"The reliability of the models elaborated for recreating the spectra of the light attenuation coefficient, d, , K λ on the basis of its measured values at 1-3 wavelengths was studied. The coefficients of the \"one-point\" (490 nm) model, elaborated earlier by A. Reinart and A. Herlevi, were tested and approved using 43 new spectra of underwater irradiance measured in 1999-2000. A new version (named C-model) allowing recreation of the spectrum of d, K λ on the basis on its measured values","PeriodicalId":250336,"journal":{"name":"Proceedings of the Estonian Academy of Sciences. Biology. Ecology","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Model calculations of diffuse attenuation coefficient spectra in lake waters\",\"authors\":\"B. Paavel, H. Arst, A. Reinart, A. Herlevi\",\"doi\":\"10.3176/biol.ecol.2006.1.05\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The reliability of the models elaborated for recreating the spectra of the light attenuation coefficient, d, , K λ on the basis of its measured values at 1-3 wavelengths was studied. The coefficients of the \\\"one-point\\\" (490 nm) model, elaborated earlier by A. Reinart and A. Herlevi, were tested and approved using 43 new spectra of underwater irradiance measured in 1999-2000. A new version (named C-model) allowing recreation of the spectrum of d, K λ on the basis on its measured values\",\"PeriodicalId\":250336,\"journal\":{\"name\":\"Proceedings of the Estonian Academy of Sciences. Biology. Ecology\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Estonian Academy of Sciences. Biology. Ecology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3176/biol.ecol.2006.1.05\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Estonian Academy of Sciences. Biology. Ecology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3176/biol.ecol.2006.1.05","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
摘要
研究了光衰减系数d,, K λ在1-3波长测量值基础上重建光谱的模型的可靠性。雷纳特(A. Reinart)和赫莱维(A. Herlevi)早先提出的“一点”(490 nm)模型的系数,在1999年至2000年期间用43个新的水下辐射光谱进行了测试和验证。一个新的版本(命名为c模型)允许在其测量值的基础上重建d, K λ的光谱
Model calculations of diffuse attenuation coefficient spectra in lake waters
The reliability of the models elaborated for recreating the spectra of the light attenuation coefficient, d, , K λ on the basis of its measured values at 1-3 wavelengths was studied. The coefficients of the "one-point" (490 nm) model, elaborated earlier by A. Reinart and A. Herlevi, were tested and approved using 43 new spectra of underwater irradiance measured in 1999-2000. A new version (named C-model) allowing recreation of the spectrum of d, K λ on the basis on its measured values