一个PET检测器模块,使用仅fpga的MVT数字转换器

D. Xi, Chen Zeng, W. Liu, Xiang Liu, L. Wan, Heejong Kim, Luyao Wang, C. Kao, Q. Xie
{"title":"一个PET检测器模块,使用仅fpga的MVT数字转换器","authors":"D. Xi, Chen Zeng, W. Liu, Xiang Liu, L. Wan, Heejong Kim, Luyao Wang, C. Kao, Q. Xie","doi":"10.1109/NSSMIC.2013.6829063","DOIUrl":null,"url":null,"abstract":"Multi-voltage threshold (MVT) is an amplitude-based sampling method. It takes timing samples when the event pulse crosses the user-defined thresholds. Only a few comparators and TDCs are required when implementing such digitizer. Previously, we have demonstrated an FPGA-only MVT digitizer based on this method. The FPGA-only MVT digitizer employs the differential I/Os in an FPGA as the required comparators and FPGA based TDCs. The implementation of this digitizer is entirely based on the FPGA. We have demonstrated that it is possible to implement a significant number of MVT digitizers by using a single FPGA. It is also flexible, as it allows us to readily modify, or add functions to, the implementation without requiring costly hardware changes. Currently, we are developing a PET detector module using the FPGA-only MVT digitizer. In this paper we describe the design and implementation of the detector module and report its performance properties. The detector module has a total detection sensitive area of 50mm × 50mm, an overall energy resolution of 15.1% FWHM at 511keV, and a module-level coincidence timing resolution of 684ps FWHM. In addition, our preliminary imaging with such detector module successfully resolves 1.6mm-diameter rods separated by 3.2mm.","PeriodicalId":246351,"journal":{"name":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A PET detector module using FPGA-only MVT digitizers\",\"authors\":\"D. Xi, Chen Zeng, W. Liu, Xiang Liu, L. Wan, Heejong Kim, Luyao Wang, C. Kao, Q. Xie\",\"doi\":\"10.1109/NSSMIC.2013.6829063\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multi-voltage threshold (MVT) is an amplitude-based sampling method. It takes timing samples when the event pulse crosses the user-defined thresholds. Only a few comparators and TDCs are required when implementing such digitizer. Previously, we have demonstrated an FPGA-only MVT digitizer based on this method. The FPGA-only MVT digitizer employs the differential I/Os in an FPGA as the required comparators and FPGA based TDCs. The implementation of this digitizer is entirely based on the FPGA. We have demonstrated that it is possible to implement a significant number of MVT digitizers by using a single FPGA. It is also flexible, as it allows us to readily modify, or add functions to, the implementation without requiring costly hardware changes. Currently, we are developing a PET detector module using the FPGA-only MVT digitizer. In this paper we describe the design and implementation of the detector module and report its performance properties. The detector module has a total detection sensitive area of 50mm × 50mm, an overall energy resolution of 15.1% FWHM at 511keV, and a module-level coincidence timing resolution of 684ps FWHM. In addition, our preliminary imaging with such detector module successfully resolves 1.6mm-diameter rods separated by 3.2mm.\",\"PeriodicalId\":246351,\"journal\":{\"name\":\"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2013.6829063\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2013.6829063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

多电压阈值(MVT)是一种基于幅值的采样方法。当事件脉冲超过用户定义的阈值时,它会进行定时采样。在实现这种数字化时,只需要几个比较器和tdc。在此之前,我们已经演示了基于该方法的仅fpga的MVT数字化仪。仅FPGA的MVT数字化仪采用FPGA中的差分I/ o作为所需的比较器和基于FPGA的tdc。该数字化仪的实现完全基于FPGA。我们已经证明,使用单个FPGA可以实现大量的MVT数字化仪。它也很灵活,因为它允许我们随时修改或向实现添加功能,而不需要昂贵的硬件更改。目前,我们正在使用仅fpga的MVT数字化仪开发PET检测器模块。本文描述了该检测器模块的设计与实现,并报告了其性能特性。检测器模块的总探测敏感面积为50mm × 50mm, 511keV时的总能量分辨率为15.1% FWHM,模块级符合定时分辨率为684ps FWHM。此外,我们使用该探测器模块进行初步成像,成功地分辨出直径1.6mm、间隔3.2mm的棒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A PET detector module using FPGA-only MVT digitizers
Multi-voltage threshold (MVT) is an amplitude-based sampling method. It takes timing samples when the event pulse crosses the user-defined thresholds. Only a few comparators and TDCs are required when implementing such digitizer. Previously, we have demonstrated an FPGA-only MVT digitizer based on this method. The FPGA-only MVT digitizer employs the differential I/Os in an FPGA as the required comparators and FPGA based TDCs. The implementation of this digitizer is entirely based on the FPGA. We have demonstrated that it is possible to implement a significant number of MVT digitizers by using a single FPGA. It is also flexible, as it allows us to readily modify, or add functions to, the implementation without requiring costly hardware changes. Currently, we are developing a PET detector module using the FPGA-only MVT digitizer. In this paper we describe the design and implementation of the detector module and report its performance properties. The detector module has a total detection sensitive area of 50mm × 50mm, an overall energy resolution of 15.1% FWHM at 511keV, and a module-level coincidence timing resolution of 684ps FWHM. In addition, our preliminary imaging with such detector module successfully resolves 1.6mm-diameter rods separated by 3.2mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Scientific Trigger Unit for space-based real-time gamma ray burst detection I - Scientific software model and simulations Study on two-cell rf-deflector cavity for ultra-short electron bunch measurement Applications of many-core technologies to on-line event reconstruction in High Energy Physics experiments Optimization of the gas system in the CMS RPC detector at the LHC Performance of the ATLAS calorimeter trigger in the LHC Run 1 data taking period
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1