{"title":"对人工耳蜗使用者在混响环境中语音清晰度的客观测量","authors":"Stefano Cosentino, T. Marquardt, D. McAlpine, T. Falk","doi":"10.1109/ISSPA.2012.6310637","DOIUrl":null,"url":null,"abstract":"This study validates a novel approach to predict speech intelligibility for Cochlear Implant users (CIs) in reverberant environments. More specifically, we explore the use of existing objective quality and intelligibility metrics, applied directly to vocoded speech degraded by room reverberation, here assessed at ten different reverberation time (RT60) values: 0 s, 0.4 s - 1.0 s (0.1 s increments), 1.5 s and 2 s. Eight objective speech intelligibility predictors (SIPs) were investigated in this study. Of these, two were non-intrusive (i.e. did not require a reference signal) audio quality measures, four were intrusive, and two were intrusive speech intelligibility indexes. Three types of vocoders were implemented to examine how speech intelligibility predictions depended on the vocoder type. These were: noise-excited vocoder, tone-excited vocoder and a FFT-based N-of-M vocoder. Experimental results show that several intrusive quality and intelligibility measures were highly correlated with exponentially fit CI intelligibility data. On the other hand, only a recently - developed non-intrusive measure showed high correlations. These evaluations suggest that CI intelligibility may be accurately assessed via objective metrics applied to vocoded speech, thus may reduce the need for expensive and time-consuming listening tests.","PeriodicalId":248763,"journal":{"name":"2012 11th International Conference on Information Science, Signal Processing and their Applications (ISSPA)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Towards objective measures of speech intelligibility for Cochlear Implant users in reverberant environments\",\"authors\":\"Stefano Cosentino, T. Marquardt, D. McAlpine, T. Falk\",\"doi\":\"10.1109/ISSPA.2012.6310637\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study validates a novel approach to predict speech intelligibility for Cochlear Implant users (CIs) in reverberant environments. More specifically, we explore the use of existing objective quality and intelligibility metrics, applied directly to vocoded speech degraded by room reverberation, here assessed at ten different reverberation time (RT60) values: 0 s, 0.4 s - 1.0 s (0.1 s increments), 1.5 s and 2 s. Eight objective speech intelligibility predictors (SIPs) were investigated in this study. Of these, two were non-intrusive (i.e. did not require a reference signal) audio quality measures, four were intrusive, and two were intrusive speech intelligibility indexes. Three types of vocoders were implemented to examine how speech intelligibility predictions depended on the vocoder type. These were: noise-excited vocoder, tone-excited vocoder and a FFT-based N-of-M vocoder. Experimental results show that several intrusive quality and intelligibility measures were highly correlated with exponentially fit CI intelligibility data. On the other hand, only a recently - developed non-intrusive measure showed high correlations. These evaluations suggest that CI intelligibility may be accurately assessed via objective metrics applied to vocoded speech, thus may reduce the need for expensive and time-consuming listening tests.\",\"PeriodicalId\":248763,\"journal\":{\"name\":\"2012 11th International Conference on Information Science, Signal Processing and their Applications (ISSPA)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 11th International Conference on Information Science, Signal Processing and their Applications (ISSPA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISSPA.2012.6310637\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 11th International Conference on Information Science, Signal Processing and their Applications (ISSPA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSPA.2012.6310637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本研究验证了一种预测人工耳蜗使用者(CIs)在混响环境下语音可理解度的新方法。更具体地说,我们探索了现有的客观质量和可理解性指标的使用,直接应用于由室内混响退化的语音编码,在这里评估了10个不同的混响时间(RT60)值:0秒,0.4秒- 1.0秒(0.1秒增量),1.5秒和2秒。本研究对8个客观语音清晰度预测因子进行了研究。其中,两个是非侵入性(即不需要参考信号)音频质量指标,四个是侵入性指标,两个是侵入性语音清晰度指标。实现了三种类型的声码器,以检查语音可理解性预测如何依赖于声码器类型。这些是:噪声激发声码器,音调激发声码器和基于fft的N-of-M声码器。实验结果表明,一些侵入性的质量和可理解性指标与指数拟合的CI可理解性数据高度相关。另一方面,只有最近发展的非侵入性测量显示出高相关性。这些评估表明,可以通过应用于语音编码语音的客观指标来准确评估CI的可理解性,从而减少对昂贵且耗时的听力测试的需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Towards objective measures of speech intelligibility for Cochlear Implant users in reverberant environments
This study validates a novel approach to predict speech intelligibility for Cochlear Implant users (CIs) in reverberant environments. More specifically, we explore the use of existing objective quality and intelligibility metrics, applied directly to vocoded speech degraded by room reverberation, here assessed at ten different reverberation time (RT60) values: 0 s, 0.4 s - 1.0 s (0.1 s increments), 1.5 s and 2 s. Eight objective speech intelligibility predictors (SIPs) were investigated in this study. Of these, two were non-intrusive (i.e. did not require a reference signal) audio quality measures, four were intrusive, and two were intrusive speech intelligibility indexes. Three types of vocoders were implemented to examine how speech intelligibility predictions depended on the vocoder type. These were: noise-excited vocoder, tone-excited vocoder and a FFT-based N-of-M vocoder. Experimental results show that several intrusive quality and intelligibility measures were highly correlated with exponentially fit CI intelligibility data. On the other hand, only a recently - developed non-intrusive measure showed high correlations. These evaluations suggest that CI intelligibility may be accurately assessed via objective metrics applied to vocoded speech, thus may reduce the need for expensive and time-consuming listening tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Online mvbf adaptation under diffuse noise environments with mimo based noise pre-filtering Hierarchical scheme for Arabic text recognition Precoder selection and rank adaptation in MIMO-OFDM Head detection using Kinect camera and its application to fall detection Wavelength and code division multiplexing toward diffuse optical imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1