{"title":"导管移位:动脉内静脉加压素输注控制胃肠道出血失败的原因之一。","authors":"S Kadir, C A Athanasoulis","doi":"10.1007/BF02552031","DOIUrl":null,"url":null,"abstract":"<p><p>Catheter dislodgement is a major cause of technical failures in intraarterial vasopressin therapy for gastrointestinal bleeding. Ten such cases were observed in the past five years. In seven patients catheter dislodgement led to recurrent bleeding during vasopressin infusion. In one patient aortic infusion of vasopressin caused recurrent bleeding and reversible acrocyanosis of the feet, and in two patients vasopressin infusion into the left renal artery resulted in chest pain and hematuria. Catheter dislodgement should be suspected if bleeding that was initially controlled recurs during vasopressin infusion.</p>","PeriodicalId":75676,"journal":{"name":"Cardiovascular radiology","volume":"1 3","pages":"187-91"},"PeriodicalIF":0.0000,"publicationDate":"1978-07-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02552031","citationCount":"3","resultStr":"{\"title\":\"Catheter dislodgement: a cause of failure of intraarterial vasopressin infusions to control gastrointestinal bleeding.\",\"authors\":\"S Kadir, C A Athanasoulis\",\"doi\":\"10.1007/BF02552031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Catheter dislodgement is a major cause of technical failures in intraarterial vasopressin therapy for gastrointestinal bleeding. Ten such cases were observed in the past five years. In seven patients catheter dislodgement led to recurrent bleeding during vasopressin infusion. In one patient aortic infusion of vasopressin caused recurrent bleeding and reversible acrocyanosis of the feet, and in two patients vasopressin infusion into the left renal artery resulted in chest pain and hematuria. Catheter dislodgement should be suspected if bleeding that was initially controlled recurs during vasopressin infusion.</p>\",\"PeriodicalId\":75676,\"journal\":{\"name\":\"Cardiovascular radiology\",\"volume\":\"1 3\",\"pages\":\"187-91\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-07-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/BF02552031\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular radiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/BF02552031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02552031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Catheter dislodgement: a cause of failure of intraarterial vasopressin infusions to control gastrointestinal bleeding.
Catheter dislodgement is a major cause of technical failures in intraarterial vasopressin therapy for gastrointestinal bleeding. Ten such cases were observed in the past five years. In seven patients catheter dislodgement led to recurrent bleeding during vasopressin infusion. In one patient aortic infusion of vasopressin caused recurrent bleeding and reversible acrocyanosis of the feet, and in two patients vasopressin infusion into the left renal artery resulted in chest pain and hematuria. Catheter dislodgement should be suspected if bleeding that was initially controlled recurs during vasopressin infusion.