{"title":"一种微网逆变器电压瞬态动态抑制控制策略","authors":"Rongliang Shi, Xing Zhang, Fang Liu, Haizhen Xu, Lei Tao","doi":"10.1109/PEAC.2014.7037855","DOIUrl":null,"url":null,"abstract":"China Machinery Industry Standard (CMIS) GB/T 12326-2008 prescribed in the islanded operation mode, microgrid inverter (MGI) output voltage dynamic transient range is less than 10% when the resistive load is switched rapidly between 0% and 100%. The three-loop power virtual synchronous generator (VSG) control methods are commonly used in MGI units to share the loads among the parallel MGIs. However, the transient output voltage of the MGI is beyond the CMIS when the resistive load steps sharply. In order to meet the CMIS, an output voltage differential feedback improved algorithm was employed. Comparing to the traditional control method, the improved method could obtain satisfying dynamic transient voltage suppression, resonance inhibition and improve system stability. These theoretical findings were eventually verified experimentally both on simulation and laboratory prototypes.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A dynamic voltage transient suppression control strategy for microgrid inverter\",\"authors\":\"Rongliang Shi, Xing Zhang, Fang Liu, Haizhen Xu, Lei Tao\",\"doi\":\"10.1109/PEAC.2014.7037855\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"China Machinery Industry Standard (CMIS) GB/T 12326-2008 prescribed in the islanded operation mode, microgrid inverter (MGI) output voltage dynamic transient range is less than 10% when the resistive load is switched rapidly between 0% and 100%. The three-loop power virtual synchronous generator (VSG) control methods are commonly used in MGI units to share the loads among the parallel MGIs. However, the transient output voltage of the MGI is beyond the CMIS when the resistive load steps sharply. In order to meet the CMIS, an output voltage differential feedback improved algorithm was employed. Comparing to the traditional control method, the improved method could obtain satisfying dynamic transient voltage suppression, resonance inhibition and improve system stability. These theoretical findings were eventually verified experimentally both on simulation and laboratory prototypes.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7037855\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7037855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A dynamic voltage transient suppression control strategy for microgrid inverter
China Machinery Industry Standard (CMIS) GB/T 12326-2008 prescribed in the islanded operation mode, microgrid inverter (MGI) output voltage dynamic transient range is less than 10% when the resistive load is switched rapidly between 0% and 100%. The three-loop power virtual synchronous generator (VSG) control methods are commonly used in MGI units to share the loads among the parallel MGIs. However, the transient output voltage of the MGI is beyond the CMIS when the resistive load steps sharply. In order to meet the CMIS, an output voltage differential feedback improved algorithm was employed. Comparing to the traditional control method, the improved method could obtain satisfying dynamic transient voltage suppression, resonance inhibition and improve system stability. These theoretical findings were eventually verified experimentally both on simulation and laboratory prototypes.