基于WAM的补充控制器对区域间振荡的阻尼

Zhijian Hu, J. Milanović
{"title":"基于WAM的补充控制器对区域间振荡的阻尼","authors":"Zhijian Hu, J. Milanović","doi":"10.1109/PES.2007.386095","DOIUrl":null,"url":null,"abstract":"The paper demonstrates the possibility to enhance the damping of inter-area oscillations using wide area measurement (WAM) based adaptive supervisory controller (ASC).. A damping controller based on the mixed-sensitivity linear matrix inequality (LMI) approach with pole-placement restriction is designed. The ASC uses the input information from conveniently located phase measurement units (PMU) in the system and dispatches supplementary control signals to the available local controllers. Different input signals to the ASC, i.e., frequency and active power generators are used and corresponding ASC performances compared. The design of the ASC is explained in detail and its performance validated by frequency and time domain simulations on a 4- machine 2-area test system.","PeriodicalId":380613,"journal":{"name":"2007 IEEE Power Engineering Society General Meeting","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":"{\"title\":\"Damping of Inter-area Oscillations by WAM Based Supplementary Controller\",\"authors\":\"Zhijian Hu, J. Milanović\",\"doi\":\"10.1109/PES.2007.386095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper demonstrates the possibility to enhance the damping of inter-area oscillations using wide area measurement (WAM) based adaptive supervisory controller (ASC).. A damping controller based on the mixed-sensitivity linear matrix inequality (LMI) approach with pole-placement restriction is designed. The ASC uses the input information from conveniently located phase measurement units (PMU) in the system and dispatches supplementary control signals to the available local controllers. Different input signals to the ASC, i.e., frequency and active power generators are used and corresponding ASC performances compared. The design of the ASC is explained in detail and its performance validated by frequency and time domain simulations on a 4- machine 2-area test system.\",\"PeriodicalId\":380613,\"journal\":{\"name\":\"2007 IEEE Power Engineering Society General Meeting\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2007.386095\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2007.386095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

摘要

本文论证了利用基于广域测量(WAM)的自适应监控控制器(ASC)增强区域间振荡阻尼的可能性。设计了一种基于混合灵敏度线性矩阵不等式(LMI)方法的具有极点位置限制的阻尼控制器。ASC使用来自系统中方便定位的相位测量单元(PMU)的输入信息,并向可用的本地控制器发送补充控制信号。使用不同的ASC输入信号,即频率和有功发电机,并比较相应的ASC性能。详细介绍了ASC的设计,并在4机2区测试系统上进行了频域和时域仿真,验证了ASC的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Damping of Inter-area Oscillations by WAM Based Supplementary Controller
The paper demonstrates the possibility to enhance the damping of inter-area oscillations using wide area measurement (WAM) based adaptive supervisory controller (ASC).. A damping controller based on the mixed-sensitivity linear matrix inequality (LMI) approach with pole-placement restriction is designed. The ASC uses the input information from conveniently located phase measurement units (PMU) in the system and dispatches supplementary control signals to the available local controllers. Different input signals to the ASC, i.e., frequency and active power generators are used and corresponding ASC performances compared. The design of the ASC is explained in detail and its performance validated by frequency and time domain simulations on a 4- machine 2-area test system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Panel on Infrastructures for Enabling Sustainable Energy Technologies Electric Industry Infrastructure for Sustainability: Climate Change and Energy Storage Sulfur Hexafluoride SF6 Proactive Reliability Management using almost Real-Time Outage Data Utilizing Real-Time Outage Data for External and Internal Reporting
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1