不同电负载条件下含硅气和非硅气环境下继电器的接触电阻特性

M. Hasegawa, N. Kobayashi, Y. Kohno
{"title":"不同电负载条件下含硅气和非硅气环境下继电器的接触电阻特性","authors":"M. Hasegawa, N. Kobayashi, Y. Kohno","doi":"10.1109/HOLM.2011.6034787","DOIUrl":null,"url":null,"abstract":"Influences of vapors evaporated from an acryl-based non-silicone-type polymeric cured material and conventional silicone-containing polymeric cured materials were evaluated with respect to their effects on contact resistance characteristics of relay contacts at an ambient temperature of 120ºC. More specifically, a commercially-available mechanical relay (AgSnIn contacts) was sealed into a metal can with one of these materials, and placed in a heating chamber to operate, at an operating frequency of 0.5 Hz, 40,000 break operations of an inductive DC 14V-1A, 14V-0.4A, 10V-1A, 5V-1A load currents, or a resistive DC 14V-1A load current. Contact resistance values were measured at every 50 operations. As a result, the relays sealed with the acryl-based non-silicone-type polymeric cured material showed no deterioration in contact resistances, irrespective of the load conditions. On the other hand, the relays sealed with the silicone-containing polymeric cured materials showed more significant deteriorations and fluctuations of the contact resistance characteristics, and certain influences of load conditions on their behaviors were recognized.","PeriodicalId":197233,"journal":{"name":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Contact Resistance Characteristics of Relays Operated in Silicone-Vapor-Containing and Non-Silicone Atmospheres with Different Electrical Load Conditions\",\"authors\":\"M. Hasegawa, N. Kobayashi, Y. Kohno\",\"doi\":\"10.1109/HOLM.2011.6034787\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Influences of vapors evaporated from an acryl-based non-silicone-type polymeric cured material and conventional silicone-containing polymeric cured materials were evaluated with respect to their effects on contact resistance characteristics of relay contacts at an ambient temperature of 120ºC. More specifically, a commercially-available mechanical relay (AgSnIn contacts) was sealed into a metal can with one of these materials, and placed in a heating chamber to operate, at an operating frequency of 0.5 Hz, 40,000 break operations of an inductive DC 14V-1A, 14V-0.4A, 10V-1A, 5V-1A load currents, or a resistive DC 14V-1A load current. Contact resistance values were measured at every 50 operations. As a result, the relays sealed with the acryl-based non-silicone-type polymeric cured material showed no deterioration in contact resistances, irrespective of the load conditions. On the other hand, the relays sealed with the silicone-containing polymeric cured materials showed more significant deteriorations and fluctuations of the contact resistance characteristics, and certain influences of load conditions on their behaviors were recognized.\",\"PeriodicalId\":197233,\"journal\":{\"name\":\"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)\",\"volume\":\"60 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/HOLM.2011.6034787\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE 57th Holm Conference on Electrical Contacts (Holm)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HOLM.2011.6034787","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在120ºC的环境温度下,评估了丙烯酸基非硅树脂型聚合物固化材料和常规含硅聚合物固化材料蒸发蒸汽对继电器触点接触电阻特性的影响。更具体地说,将商用机械继电器(AgSnIn触点)密封在金属罐中,使用其中一种材料,并放置在加热室中,在0.5 Hz的工作频率下,对电感DC 14V-1A, 14V-0.4A, 10V-1A, 5V-1A负载电流或电阻DC 14V-1A负载电流进行40,000次断开操作。每50次操作测量接触电阻值。结果,用丙烯酸基非硅树脂型聚合物固化材料密封的继电器,无论负载条件如何,接触电阻都没有恶化。另一方面,用含硅聚合物固化材料密封的继电器接触电阻特性的劣化和波动更为明显,并且负载条件对其行为有一定的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Contact Resistance Characteristics of Relays Operated in Silicone-Vapor-Containing and Non-Silicone Atmospheres with Different Electrical Load Conditions
Influences of vapors evaporated from an acryl-based non-silicone-type polymeric cured material and conventional silicone-containing polymeric cured materials were evaluated with respect to their effects on contact resistance characteristics of relay contacts at an ambient temperature of 120ºC. More specifically, a commercially-available mechanical relay (AgSnIn contacts) was sealed into a metal can with one of these materials, and placed in a heating chamber to operate, at an operating frequency of 0.5 Hz, 40,000 break operations of an inductive DC 14V-1A, 14V-0.4A, 10V-1A, 5V-1A load currents, or a resistive DC 14V-1A load current. Contact resistance values were measured at every 50 operations. As a result, the relays sealed with the acryl-based non-silicone-type polymeric cured material showed no deterioration in contact resistances, irrespective of the load conditions. On the other hand, the relays sealed with the silicone-containing polymeric cured materials showed more significant deteriorations and fluctuations of the contact resistance characteristics, and certain influences of load conditions on their behaviors were recognized.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Study on Mobile Communication Device Structure Design Resisting Dust Particles Ingress High Current Arc Erosion on Copper Electrodes in Air Contact Resistance Characteristics of Relays Operated in Silicone-Vapor-Containing and Non-Silicone Atmospheres with Different Electrical Load Conditions The Influence of the Organic Compounds on the Contaminated Electrical Contacts There is Tin and there is Tin - Characterisation of Tribological and Electrical Properties of Electroplated Tin Surfaces
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1