{"title":"油浸热升级纸的老化","authors":"K. Liland, Marit-helen Glomm Ese, C. M. Selsbak, L. Lundgaard","doi":"10.1109/ICDL.2011.6015488","DOIUrl":null,"url":null,"abstract":"Investigation of the difference in the ageing process for several thermally upgraded and non-upgraded papers in transformer oil was performed. We observed that the level of nitrogen in the papers is crucial for the resistance towards hydrolysis. One of the papers in the experiment did not fulfil the upgrade specification with respect to the nitrogen level (data sheet). For hydrolysis of wet oil impregnated samples in argon atmosphere the upgraded papers seem to degrade less than non-upgraded papers. The paper with highest level of nitrogen degrades less than those with lower levels. The Insuldur process seems to be the best way of thermally upgrading the paper (Upgrade 1) and this also gives the highest level of nitrogen. For one of the upgraded samples (Upgrade 2) the nitrogen disappears completely after startup and this paper behaves as non-upgraded for the highest temperature. Dry oil impregnated paper (0.2% water content) under argon atmosphere does not seem to be hydrolysed and ages at a very slow rate. In the case of oxidation of dry oil impregnated samples (0.2% water content) in air there are initially no significant difference between non-upgraded and upgraded papers. However, the upgraded papers seem to have an improved performance after the water production from ageing becomes significant. The oxidation activation energy for non-upgraded paper is lower compared to hydrolysis and for upgraded paper this difference is smaller.","PeriodicalId":364451,"journal":{"name":"2011 IEEE International Conference on Dielectric Liquids","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Ageing of oil impregnated thermally upgraded papers\",\"authors\":\"K. Liland, Marit-helen Glomm Ese, C. M. Selsbak, L. Lundgaard\",\"doi\":\"10.1109/ICDL.2011.6015488\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Investigation of the difference in the ageing process for several thermally upgraded and non-upgraded papers in transformer oil was performed. We observed that the level of nitrogen in the papers is crucial for the resistance towards hydrolysis. One of the papers in the experiment did not fulfil the upgrade specification with respect to the nitrogen level (data sheet). For hydrolysis of wet oil impregnated samples in argon atmosphere the upgraded papers seem to degrade less than non-upgraded papers. The paper with highest level of nitrogen degrades less than those with lower levels. The Insuldur process seems to be the best way of thermally upgrading the paper (Upgrade 1) and this also gives the highest level of nitrogen. For one of the upgraded samples (Upgrade 2) the nitrogen disappears completely after startup and this paper behaves as non-upgraded for the highest temperature. Dry oil impregnated paper (0.2% water content) under argon atmosphere does not seem to be hydrolysed and ages at a very slow rate. In the case of oxidation of dry oil impregnated samples (0.2% water content) in air there are initially no significant difference between non-upgraded and upgraded papers. However, the upgraded papers seem to have an improved performance after the water production from ageing becomes significant. The oxidation activation energy for non-upgraded paper is lower compared to hydrolysis and for upgraded paper this difference is smaller.\",\"PeriodicalId\":364451,\"journal\":{\"name\":\"2011 IEEE International Conference on Dielectric Liquids\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 IEEE International Conference on Dielectric Liquids\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICDL.2011.6015488\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Dielectric Liquids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2011.6015488","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

研究了几种热升级纸和非升级纸在变压器油中老化过程的差异。我们观察到,氮在纸的水平是至关重要的抗水解。实验中有一篇论文的氮含量(数据表)不符合升级规范。对于湿油浸渍样品在氩气气氛中的水解,升级纸似乎比未升级纸的降解程度要小。氮含量高的纸比氮含量低的纸降解得少。Insuldur工艺似乎是对纸张进行热升级的最佳方法(升级1),这也提供了最高水平的氮。其中升级后的样品(升级2),氮气在启动后完全消失,该材料在最高温度下表现为未升级。干油浸渍纸(0.2%含水量)在氩气气氛下似乎不水解,老化速度非常慢。在干燥油浸渍样品(含水量0.2%)在空气中氧化的情况下,未升级和升级的纸张最初没有显著差异。然而,升级后的纸张在老化产水量显著增加后,其性能似乎有所提高。与水解相比,未升级纸的氧化活化能较低,而升级纸的氧化活化能差异较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ageing of oil impregnated thermally upgraded papers
Investigation of the difference in the ageing process for several thermally upgraded and non-upgraded papers in transformer oil was performed. We observed that the level of nitrogen in the papers is crucial for the resistance towards hydrolysis. One of the papers in the experiment did not fulfil the upgrade specification with respect to the nitrogen level (data sheet). For hydrolysis of wet oil impregnated samples in argon atmosphere the upgraded papers seem to degrade less than non-upgraded papers. The paper with highest level of nitrogen degrades less than those with lower levels. The Insuldur process seems to be the best way of thermally upgrading the paper (Upgrade 1) and this also gives the highest level of nitrogen. For one of the upgraded samples (Upgrade 2) the nitrogen disappears completely after startup and this paper behaves as non-upgraded for the highest temperature. Dry oil impregnated paper (0.2% water content) under argon atmosphere does not seem to be hydrolysed and ages at a very slow rate. In the case of oxidation of dry oil impregnated samples (0.2% water content) in air there are initially no significant difference between non-upgraded and upgraded papers. However, the upgraded papers seem to have an improved performance after the water production from ageing becomes significant. The oxidation activation energy for non-upgraded paper is lower compared to hydrolysis and for upgraded paper this difference is smaller.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Spectra emitted by helium excited by corona discharge Review of Kraft paper/natural ester fluid insulation system aging Surface treeing on pressboard barriers in synthetic and natural ester liquids under AC stress Partial discharges and light emission from ceramic substrates embedded in liquids and gels Time-dynamic oxidation stability studies of mineral insulating oils
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1