{"title":"用于VPI旋转电机新线圈和定子绕组质量评估的耗散系数和局部放电测量","authors":"A. Contin, G. Peruzzi","doi":"10.1109/EIC.2018.8481026","DOIUrl":null,"url":null,"abstract":"The correlation between Dissipation Factor (DF) and Partial Discharge (PD) test results in the evaluation of the stator insulation of ac rotating machines, is discussed in this paper. It is well known that DF provides information on the global losses occurring in insulation systems but it does not provide any indication of the distribution of these losses. Above PD Inception Voltage (PDIV), increments of DF values are mainly due to PD in localized defects. Thanks to PD-signal separation and PD sub-pattern analysis, the causes of DF increments can be explained with more accuracy. Moreover, by comparing DF values recorded below the PDIV and PD patterns due to distributed micro-voids, the quality of the impregnation process in terms of void content, can be better evaluated. These results clearly show that the joint use of these two test methods can significantly improve the information on the conditions and the quality of the insulation system.","PeriodicalId":184139,"journal":{"name":"2018 IEEE Electrical Insulation Conference (EIC)","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Dissipation Factor and Partial Discharge Measurements for the Quality Assessment of New Coils and Stator Windings of VPI Rotating Machines\",\"authors\":\"A. Contin, G. Peruzzi\",\"doi\":\"10.1109/EIC.2018.8481026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The correlation between Dissipation Factor (DF) and Partial Discharge (PD) test results in the evaluation of the stator insulation of ac rotating machines, is discussed in this paper. It is well known that DF provides information on the global losses occurring in insulation systems but it does not provide any indication of the distribution of these losses. Above PD Inception Voltage (PDIV), increments of DF values are mainly due to PD in localized defects. Thanks to PD-signal separation and PD sub-pattern analysis, the causes of DF increments can be explained with more accuracy. Moreover, by comparing DF values recorded below the PDIV and PD patterns due to distributed micro-voids, the quality of the impregnation process in terms of void content, can be better evaluated. These results clearly show that the joint use of these two test methods can significantly improve the information on the conditions and the quality of the insulation system.\",\"PeriodicalId\":184139,\"journal\":{\"name\":\"2018 IEEE Electrical Insulation Conference (EIC)\",\"volume\":\"110 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Electrical Insulation Conference (EIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.2018.8481026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Electrical Insulation Conference (EIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.2018.8481026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

讨论了交流旋转电机定子绝缘评定中耗散系数(DF)与局部放电(PD)试验结果之间的关系。众所周知,DF提供了有关绝缘系统中发生的全球损耗的信息,但它没有提供这些损耗分布的任何指示。在PD起始电压(PDIV)以上,DF值的增加主要是由于局部缺陷的PD。通过PD信号分离和PD子图分析,可以更准确地解释DF增量的原因。此外,通过比较PDIV和PD模式下由于分布微孔洞而记录的DF值,可以更好地评价浸渍过程中孔洞含量的质量。这些结果清楚地表明,这两种测试方法的联合使用可以显著改善绝缘系统的状况和质量信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dissipation Factor and Partial Discharge Measurements for the Quality Assessment of New Coils and Stator Windings of VPI Rotating Machines
The correlation between Dissipation Factor (DF) and Partial Discharge (PD) test results in the evaluation of the stator insulation of ac rotating machines, is discussed in this paper. It is well known that DF provides information on the global losses occurring in insulation systems but it does not provide any indication of the distribution of these losses. Above PD Inception Voltage (PDIV), increments of DF values are mainly due to PD in localized defects. Thanks to PD-signal separation and PD sub-pattern analysis, the causes of DF increments can be explained with more accuracy. Moreover, by comparing DF values recorded below the PDIV and PD patterns due to distributed micro-voids, the quality of the impregnation process in terms of void content, can be better evaluated. These results clearly show that the joint use of these two test methods can significantly improve the information on the conditions and the quality of the insulation system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Experimental Research on Flashover Characteristics of Insulator with N2 Dissolved Gas Analysis (DGA) of Arc Discharge Fault in Transformer Insulation Oils (Ester and Mineral Oils) Nonparametric Kernel Density Estimation Model of Transformer Health Based on Dissolved Gases in Oil Experimental validation of a moisture sensor for cellulosic insulation of power transformers Development Process of Vibration Sparking Erosion on Stator Bars
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1