变电站隔离开关引起的电磁干扰耦合机制的评估:实验设计和初步结果

P. Pretorius, A. Britten, J. Van Coller, J. Reynders
{"title":"变电站隔离开关引起的电磁干扰耦合机制的评估:实验设计和初步结果","authors":"P. Pretorius, A. Britten, J. Van Coller, J. Reynders","doi":"10.1109/COMSIG.1998.736972","DOIUrl":null,"url":null,"abstract":"The potential threat that electromagnetic disturbances generated during disconnector switching poses to substation-based control, protection and communication equipment has been raised in previously published literature. A better understanding of the coupling mechanisms involved can assist engineers in designing systems that are immune to these disturbances. An experiment designed to evaluate inductive, capacitive and conductive interference in the context of coupled unwanted common mode currents is described.","PeriodicalId":294473,"journal":{"name":"Proceedings of the 1998 South African Symposium on Communications and Signal Processing-COMSIG '98 (Cat. No. 98EX214)","volume":"495 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Evaluation of the coupling mechanisms of electromagnetic disturbances resulting from disconnector switching in substations: experimental design and initial results\",\"authors\":\"P. Pretorius, A. Britten, J. Van Coller, J. Reynders\",\"doi\":\"10.1109/COMSIG.1998.736972\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The potential threat that electromagnetic disturbances generated during disconnector switching poses to substation-based control, protection and communication equipment has been raised in previously published literature. A better understanding of the coupling mechanisms involved can assist engineers in designing systems that are immune to these disturbances. An experiment designed to evaluate inductive, capacitive and conductive interference in the context of coupled unwanted common mode currents is described.\",\"PeriodicalId\":294473,\"journal\":{\"name\":\"Proceedings of the 1998 South African Symposium on Communications and Signal Processing-COMSIG '98 (Cat. No. 98EX214)\",\"volume\":\"495 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-09-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 1998 South African Symposium on Communications and Signal Processing-COMSIG '98 (Cat. No. 98EX214)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/COMSIG.1998.736972\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1998 South African Symposium on Communications and Signal Processing-COMSIG '98 (Cat. No. 98EX214)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COMSIG.1998.736972","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在先前发表的文献中,已经提出了隔离开关过程中产生的电磁干扰对基于变电站的控制、保护和通信设备的潜在威胁。更好地理解所涉及的耦合机制可以帮助工程师设计不受这些干扰影响的系统。本文描述了一种在不需要的共模电流耦合情况下评估电感、电容和导电干扰的实验。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the coupling mechanisms of electromagnetic disturbances resulting from disconnector switching in substations: experimental design and initial results
The potential threat that electromagnetic disturbances generated during disconnector switching poses to substation-based control, protection and communication equipment has been raised in previously published literature. A better understanding of the coupling mechanisms involved can assist engineers in designing systems that are immune to these disturbances. An experiment designed to evaluate inductive, capacitive and conductive interference in the context of coupled unwanted common mode currents is described.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hybrid combination of knowledge- and cepstral-based features for phoneme recognition Signal processing of the auditory brainstem response: clinical effects of variations in fast Fourier transform analysis On slotted waveguide antenna design at Ka-band An acoustical analysis of the cardinal vowels as spoken by Daniel Jones Stepped-frequency processing by reconstruction of target reflectivity spectrum
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1