{"title":"瓦片纤维强子量热计的性能","authors":"T. Takeshita","doi":"10.1063/1.1394459","DOIUrl":null,"url":null,"abstract":"A sandwich type of the tile-fiber hadron calorimeter was constructed and tested at KEK and Fermilab. The energy resolution, linearity and e/π ratio were measured. The results indicate that the detector is quite promising for the calorimeter of the Linear Collider detector.","PeriodicalId":325505,"journal":{"name":"Physics and experiments with future linear e+ e- colliders","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance of the tile-fiber hadron calorimeter\",\"authors\":\"T. Takeshita\",\"doi\":\"10.1063/1.1394459\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A sandwich type of the tile-fiber hadron calorimeter was constructed and tested at KEK and Fermilab. The energy resolution, linearity and e/π ratio were measured. The results indicate that the detector is quite promising for the calorimeter of the Linear Collider detector.\",\"PeriodicalId\":325505,\"journal\":{\"name\":\"Physics and experiments with future linear e+ e- colliders\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-09-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Physics and experiments with future linear e+ e- colliders\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/1.1394459\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics and experiments with future linear e+ e- colliders","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.1394459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A sandwich type of the tile-fiber hadron calorimeter was constructed and tested at KEK and Fermilab. The energy resolution, linearity and e/π ratio were measured. The results indicate that the detector is quite promising for the calorimeter of the Linear Collider detector.