具有相关双计数噪声抑制的超灵敏CMOS磁生物传感器阵列

Hua Wang, Shohei Kosai, Constantine Sideris, A. Hajimiri
{"title":"具有相关双计数噪声抑制的超灵敏CMOS磁生物传感器阵列","authors":"Hua Wang, Shohei Kosai, Constantine Sideris, A. Hajimiri","doi":"10.1109/MWSYM.2010.5516851","DOIUrl":null,"url":null,"abstract":"This paper presents a scalable and ultrasensitive frequency-shift magnetic biosensing array scheme. The theoretical limit of the sensor noise floor is shown to be dominated by the phase noise of the sensing oscillators. To increase the sensitivity, a noise suppression technique, Correlated Double Counting (CDC), is proposed with no power overhead. As an implementation example, a 64-cell sensor array is designed in a standard 65nm CMOS process. The CDC scheme achieves an additional 6dB noise suppression. The magnetic sensing capability of the presented sensor is verified by detecting micron size magnetic particles with an SNR of 14.6dB for a single bead and an effective dynamic range of at least 74.5dB.","PeriodicalId":341557,"journal":{"name":"2010 IEEE MTT-S International Microwave Symposium","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-05-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"36","resultStr":"{\"title\":\"An ultrasensitive CMOS magnetic biosensor array with correlated double counting noise suppression\",\"authors\":\"Hua Wang, Shohei Kosai, Constantine Sideris, A. Hajimiri\",\"doi\":\"10.1109/MWSYM.2010.5516851\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a scalable and ultrasensitive frequency-shift magnetic biosensing array scheme. The theoretical limit of the sensor noise floor is shown to be dominated by the phase noise of the sensing oscillators. To increase the sensitivity, a noise suppression technique, Correlated Double Counting (CDC), is proposed with no power overhead. As an implementation example, a 64-cell sensor array is designed in a standard 65nm CMOS process. The CDC scheme achieves an additional 6dB noise suppression. The magnetic sensing capability of the presented sensor is verified by detecting micron size magnetic particles with an SNR of 14.6dB for a single bead and an effective dynamic range of at least 74.5dB.\",\"PeriodicalId\":341557,\"journal\":{\"name\":\"2010 IEEE MTT-S International Microwave Symposium\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"36\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE MTT-S International Microwave Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MWSYM.2010.5516851\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE MTT-S International Microwave Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2010.5516851","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 36

摘要

提出了一种可扩展的超灵敏移频磁生物传感阵列方案。传感器本底噪声的理论极限是由传感振荡器的相位噪声决定的。为了提高灵敏度,提出了一种无功率开销的噪声抑制技术——相关双计数(CDC)。作为实现示例,采用标准65nm CMOS工艺设计了64单元传感器阵列。CDC方案实现了额外的6dB噪声抑制。通过对微米级磁颗粒的检测,验证了该传感器的磁传感能力,单个磁头的信噪比为14.6dB,有效动态范围至少为74.5dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An ultrasensitive CMOS magnetic biosensor array with correlated double counting noise suppression
This paper presents a scalable and ultrasensitive frequency-shift magnetic biosensing array scheme. The theoretical limit of the sensor noise floor is shown to be dominated by the phase noise of the sensing oscillators. To increase the sensitivity, a noise suppression technique, Correlated Double Counting (CDC), is proposed with no power overhead. As an implementation example, a 64-cell sensor array is designed in a standard 65nm CMOS process. The CDC scheme achieves an additional 6dB noise suppression. The magnetic sensing capability of the presented sensor is verified by detecting micron size magnetic particles with an SNR of 14.6dB for a single bead and an effective dynamic range of at least 74.5dB.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A new approach to design low cost, low complexity phased arrays Use of ground planes within the spatial images technique: Application to the analysis of rectangular multilayered shielded enclosures Negative and zero group velocity in microstrip/negative-refractive-index transmission-line couplers A dual-mode mm-wave injection-locked frequency divider with greater than 18% locking range in 65nm CMOS Asymmetric multilevel outphasing transmitter using class-E PAs with discrete pulse width modulation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1