不同种植间距对下颌种植-保留全覆盖义齿固位和应力分布的影响(一项体外研究)。

M. Allam, Diab Alhadad, A. Shoaeb
{"title":"不同种植间距对下颌种植-保留全覆盖义齿固位和应力分布的影响(一项体外研究)。","authors":"M. Allam, Diab Alhadad, A. Shoaeb","doi":"10.21608/ajdsm.2020.48428.1131","DOIUrl":null,"url":null,"abstract":"Objective: The loss of retention or adjustment of overdentures was the most commonly reported complication type in the dental office. So, this study was aimed to evaluate the retention and stress distribution induced in implant-retained overdenture with different inter- implant distance in vitro study. Materials and Methods: Six implant-retained overdenture models were fabricated on acrylic models with two screwed implants at three-different interimplant distances (19 mm, 23 mm, and 29 mm) to measure the overdenture retention using digital force gauge as well as to the stress distribution around the dental implant using strain gauge with unilateral load application at the second premolar, first molar, and the second molar sites. Results: The results of the retention test, revealed no statistically significant difference among the tested groups. While the strain results showed a statistically significant difference between all tested groups. Conclusion: The smaller interimplant distance could improve the retention of the overdenture as well as it could allow better stress distribution around the dental implants.","PeriodicalId":117944,"journal":{"name":"Al-Azhar Journal of Dental Science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Retention and stress distribution induced in mandibular implant-retained complete overdenture with different interimplant distance (An In-Vitro study).\",\"authors\":\"M. Allam, Diab Alhadad, A. Shoaeb\",\"doi\":\"10.21608/ajdsm.2020.48428.1131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: The loss of retention or adjustment of overdentures was the most commonly reported complication type in the dental office. So, this study was aimed to evaluate the retention and stress distribution induced in implant-retained overdenture with different inter- implant distance in vitro study. Materials and Methods: Six implant-retained overdenture models were fabricated on acrylic models with two screwed implants at three-different interimplant distances (19 mm, 23 mm, and 29 mm) to measure the overdenture retention using digital force gauge as well as to the stress distribution around the dental implant using strain gauge with unilateral load application at the second premolar, first molar, and the second molar sites. Results: The results of the retention test, revealed no statistically significant difference among the tested groups. While the strain results showed a statistically significant difference between all tested groups. Conclusion: The smaller interimplant distance could improve the retention of the overdenture as well as it could allow better stress distribution around the dental implants.\",\"PeriodicalId\":117944,\"journal\":{\"name\":\"Al-Azhar Journal of Dental Science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al-Azhar Journal of Dental Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/ajdsm.2020.48428.1131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Journal of Dental Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/ajdsm.2020.48428.1131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:覆盖义齿固位或调整缺失是口腔外科最常见的并发症类型。因此,本研究旨在评估不同种植间距离对种植义齿固位和应力分布的影响。材料与方法:在丙烯酸树脂模型上制作6个种植体固位覆盖义齿模型,采用两颗螺钉种植体,种植体间距离分别为19 mm、23 mm和29 mm,采用数字力计测量覆盖义齿固位情况,采用应变计测量种植体周围第二前磨牙、第一磨牙和第二磨牙的应力分布。结果:留置测试结果显示各组间差异无统计学意义。而菌株结果显示各组间差异有统计学意义。结论:种植间距越小,覆盖义齿固位越好,种植体周围应力分布越好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Retention and stress distribution induced in mandibular implant-retained complete overdenture with different interimplant distance (An In-Vitro study).
Objective: The loss of retention or adjustment of overdentures was the most commonly reported complication type in the dental office. So, this study was aimed to evaluate the retention and stress distribution induced in implant-retained overdenture with different inter- implant distance in vitro study. Materials and Methods: Six implant-retained overdenture models were fabricated on acrylic models with two screwed implants at three-different interimplant distances (19 mm, 23 mm, and 29 mm) to measure the overdenture retention using digital force gauge as well as to the stress distribution around the dental implant using strain gauge with unilateral load application at the second premolar, first molar, and the second molar sites. Results: The results of the retention test, revealed no statistically significant difference among the tested groups. While the strain results showed a statistically significant difference between all tested groups. Conclusion: The smaller interimplant distance could improve the retention of the overdenture as well as it could allow better stress distribution around the dental implants.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of clinical effect of titanium-prepared platelet-rich fibrin and platelet- rich fibrin in treatment of gingival recession Fracture resistance of CAD CAM endocrowns bonded to teeth with different number of remaining walls :An In-Vitro Study. Evaluation of the effect of vitamin D on the salivary and serum levels of interleukin-8 in patients with periodontitis stage I and II grade A. The Effectiveness Of Topical Avocado In The Treatment Of Minor Recurrent Aphthous Ulceration: A Randomized Controlled Clinical Trial Modulus of Elasticity of Different Resin Denture Base Materials: A Comparative Study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1