双眼和单眼视觉

H. Uozato
{"title":"双眼和单眼视觉","authors":"H. Uozato","doi":"10.4263/JORTHOPTIC.35.61","DOIUrl":null,"url":null,"abstract":"The measurement of visual functions (such as refraction, acuity, and so on) is the first essential part of any ocular examination and the process being assessed is complex and requires the interaction of many factors, both physiological and psychological. Pupil size is an important factor in relation to visual functions such as refraction, acuity, contrast sensitivity and so on. Its effects, however, are complex. We investigated the effects of pupil size and optical aberrations on visual functions under binocular and monocular conditions. Pupil diameters were continuously recorded during examination of contrast sensitivity (CS) and visual acuity (log MAR scale). Aberrometry was measured with OPD-Scan. Zernike coefficients were calculated for the pupil diameters under binocular and monocular conditions using Schwiegerling's method of recalculating the expansion coefficient. Significant differences were found between binocular log CS and monocular log CS. Binocular visual acuity was significantly better than monocular visual acuity. Mean pupil diameters examined under binocular conditions decreased significantly as compared to monocular conditions. With the increases in pupil diameter, optical aberrations increased significantly. These results suggest that decrease in pupil diameter from monocular to binocular conditions causes a decrease in optical aberration, resulting in the improved subjective visual performance. We should consider the major effects of pupil size change on vision testing from monocular to binocular viewing condition, and vice versa.","PeriodicalId":205688,"journal":{"name":"Japanese orthoptic journal","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Binocular and Monocular Vision\",\"authors\":\"H. Uozato\",\"doi\":\"10.4263/JORTHOPTIC.35.61\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The measurement of visual functions (such as refraction, acuity, and so on) is the first essential part of any ocular examination and the process being assessed is complex and requires the interaction of many factors, both physiological and psychological. Pupil size is an important factor in relation to visual functions such as refraction, acuity, contrast sensitivity and so on. Its effects, however, are complex. We investigated the effects of pupil size and optical aberrations on visual functions under binocular and monocular conditions. Pupil diameters were continuously recorded during examination of contrast sensitivity (CS) and visual acuity (log MAR scale). Aberrometry was measured with OPD-Scan. Zernike coefficients were calculated for the pupil diameters under binocular and monocular conditions using Schwiegerling's method of recalculating the expansion coefficient. Significant differences were found between binocular log CS and monocular log CS. Binocular visual acuity was significantly better than monocular visual acuity. Mean pupil diameters examined under binocular conditions decreased significantly as compared to monocular conditions. With the increases in pupil diameter, optical aberrations increased significantly. These results suggest that decrease in pupil diameter from monocular to binocular conditions causes a decrease in optical aberration, resulting in the improved subjective visual performance. We should consider the major effects of pupil size change on vision testing from monocular to binocular viewing condition, and vice versa.\",\"PeriodicalId\":205688,\"journal\":{\"name\":\"Japanese orthoptic journal\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese orthoptic journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4263/JORTHOPTIC.35.61\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese orthoptic journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4263/JORTHOPTIC.35.61","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

视觉功能的测量(如屈光、敏锐度等)是任何眼科检查的第一个重要部分,评估过程很复杂,需要许多生理和心理因素的相互作用。瞳孔大小是一个重要的因素,关系到视觉功能,如屈光,敏锐度,对比敏感度等。然而,它的影响是复杂的。我们研究了双眼和单眼条件下瞳孔大小和光学像差对视觉功能的影响。在对比敏感度(CS)和视敏度(对数MAR量表)检查时连续记录瞳孔直径。用OPD-Scan测量像差。采用Schwiegerling法重新计算瞳孔膨胀系数,计算了双眼和单眼条件下瞳孔直径的Zernike系数。双眼CS与单眼CS有显著性差异。双眼视力明显优于单眼视力。与单眼条件相比,双眼条件下的平均瞳孔直径明显减小。随着瞳孔直径的增大,光学像差明显增大。这些结果表明,从单眼到双眼,瞳孔直径的减小会导致光学像差的降低,从而提高主观视觉表现。我们应该考虑瞳孔大小变化对单眼和双眼视力测试的主要影响,反之亦然。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Binocular and Monocular Vision
The measurement of visual functions (such as refraction, acuity, and so on) is the first essential part of any ocular examination and the process being assessed is complex and requires the interaction of many factors, both physiological and psychological. Pupil size is an important factor in relation to visual functions such as refraction, acuity, contrast sensitivity and so on. Its effects, however, are complex. We investigated the effects of pupil size and optical aberrations on visual functions under binocular and monocular conditions. Pupil diameters were continuously recorded during examination of contrast sensitivity (CS) and visual acuity (log MAR scale). Aberrometry was measured with OPD-Scan. Zernike coefficients were calculated for the pupil diameters under binocular and monocular conditions using Schwiegerling's method of recalculating the expansion coefficient. Significant differences were found between binocular log CS and monocular log CS. Binocular visual acuity was significantly better than monocular visual acuity. Mean pupil diameters examined under binocular conditions decreased significantly as compared to monocular conditions. With the increases in pupil diameter, optical aberrations increased significantly. These results suggest that decrease in pupil diameter from monocular to binocular conditions causes a decrease in optical aberration, resulting in the improved subjective visual performance. We should consider the major effects of pupil size change on vision testing from monocular to binocular viewing condition, and vice versa.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Haidinger's brushesをもちいた視覚健診の試み 地域と連携した視能訓練士教育への取り組み 1.患者団体の受け入れ反応 視能訓練士教育における検影法習得の試み : 第1報 教育プログラムと基本技術の習得 New Aniseikonia Testの可視光分析試験 「本音で語ろう間欠性外斜視」手術の立場から………外直筋後転術
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1