Jae Hyun Lee, B. Kim, Sun-Hee Kim, K. Yom, Sung-Mo Choi
{"title":"t型加劲梁柱组合连接强度公式提出及型式发展","authors":"Jae Hyun Lee, B. Kim, Sun-Hee Kim, K. Yom, Sung-Mo Choi","doi":"10.11004/KOSACS.2018.9.1.026","DOIUrl":null,"url":null,"abstract":"As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618 X 618mm) by a fabrication facilities. And due to charateristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment. ","PeriodicalId":320267,"journal":{"name":"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018","volume":"138 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Proposal of Strength Formula and Type Development of Composite Mega Column to Beam Connections with T-shaped Stiffener\",\"authors\":\"Jae Hyun Lee, B. Kim, Sun-Hee Kim, K. Yom, Sung-Mo Choi\",\"doi\":\"10.11004/KOSACS.2018.9.1.026\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618 X 618mm) by a fabrication facilities. And due to charateristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment. \",\"PeriodicalId\":320267,\"journal\":{\"name\":\"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018\",\"volume\":\"138 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11004/KOSACS.2018.9.1.026\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11004/KOSACS.2018.9.1.026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
随着建筑物变得越来越大,对超大型组合柱(直径超过1米)的需求也在增加。自2005年以来,我们已经开发并商业化了结构稳定和经济的冷弯带肋钢焊接组合CFT柱(ACT柱I)。然而,制造设施的横截面尺寸(618 X 618mm)受到限制。并且由于截面闭合的特点,对弯矩框架连接的施工有一定的限制。复合巨柱(ACT柱II)具有形成封闭截面的相同概念。但为了扩大截面尺寸,在冷弯型钢之间插入厚板。由于组合巨型柱可以控制厚板的厚度和宽度,因此可以直接连接钢或组合梁。本文提出了以t型加劲筋为内隔板的组合式巨型柱-梁连接的强度公式,并通过有限元分析和简单拉伸试验进行了验证。
Proposal of Strength Formula and Type Development of Composite Mega Column to Beam Connections with T-shaped Stiffener
As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618 X 618mm) by a fabrication facilities. And due to charateristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment.