{"title":"有效的四标准校准程序的六端口反射计","authors":"L. Qiao, S. Yeo","doi":"10.1109/IMTC.1994.351938","DOIUrl":null,"url":null,"abstract":"A more efficient implementation of an earlier four-standard calibration procedure for six-port reflectometers (utilizing simple iteration computations instead of other more cumbersome optimization techniques) is presented. Test results show that the calibration software that has been developed is capable of yielding reasonably good accuracies even in the presence of measurement noise.<<ETX>>","PeriodicalId":231484,"journal":{"name":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Efficient four-standard calibration procedure for six-port reflectometers\",\"authors\":\"L. Qiao, S. Yeo\",\"doi\":\"10.1109/IMTC.1994.351938\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A more efficient implementation of an earlier four-standard calibration procedure for six-port reflectometers (utilizing simple iteration computations instead of other more cumbersome optimization techniques) is presented. Test results show that the calibration software that has been developed is capable of yielding reasonably good accuracies even in the presence of measurement noise.<<ETX>>\",\"PeriodicalId\":231484,\"journal\":{\"name\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMTC.1994.351938\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1994.351938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Efficient four-standard calibration procedure for six-port reflectometers
A more efficient implementation of an earlier four-standard calibration procedure for six-port reflectometers (utilizing simple iteration computations instead of other more cumbersome optimization techniques) is presented. Test results show that the calibration software that has been developed is capable of yielding reasonably good accuracies even in the presence of measurement noise.<>