利用ASRU在MV级上的应用对WEC的无功功率进行调节

Ivan Šperlín, J. Gurecký
{"title":"利用ASRU在MV级上的应用对WEC的无功功率进行调节","authors":"Ivan Šperlín, J. Gurecký","doi":"10.1109/EPE.2017.7967254","DOIUrl":null,"url":null,"abstract":"This paper is focused on challenges related to an increased quantity of distribution energy resources connected to the distribution network within the context of newly defined requirements ENTSO-E, follow-up European standards TS 50549 and codes of distribution system operators on regulation of voltage through control of the reactive power in terms of P-Q diagram. A high number of connected and operated distribution energy resources results in changes in quality parameters of voltage in a distribution grid. The evaluation of the measured parameters enables to detect overvoltage or voltage fluctuations that are not in accordance with requirements of EN 50160 standard. This paper describes courses of voltage during operation of a wind energy converter (WEC) operated in parallel with the CEZ Distribuce distribution network (DN) on medium voltage (MV) level with the prescribed control of the reactive power to a fixed value of a power factor and the control of the reactive power depending on voltage. The measurement results of U, P, Q values evaluate an influence of the voltage reactive power in a point of connection of a power generating plant to the grid with regard to keeping the voltage within a range of operating limits.","PeriodicalId":201464,"journal":{"name":"2017 18th International Scientific Conference on Electric Power Engineering (EPE)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Regulation of the reactive power of a WEC using the ASRU application on MV level\",\"authors\":\"Ivan Šperlín, J. Gurecký\",\"doi\":\"10.1109/EPE.2017.7967254\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper is focused on challenges related to an increased quantity of distribution energy resources connected to the distribution network within the context of newly defined requirements ENTSO-E, follow-up European standards TS 50549 and codes of distribution system operators on regulation of voltage through control of the reactive power in terms of P-Q diagram. A high number of connected and operated distribution energy resources results in changes in quality parameters of voltage in a distribution grid. The evaluation of the measured parameters enables to detect overvoltage or voltage fluctuations that are not in accordance with requirements of EN 50160 standard. This paper describes courses of voltage during operation of a wind energy converter (WEC) operated in parallel with the CEZ Distribuce distribution network (DN) on medium voltage (MV) level with the prescribed control of the reactive power to a fixed value of a power factor and the control of the reactive power depending on voltage. The measurement results of U, P, Q values evaluate an influence of the voltage reactive power in a point of connection of a power generating plant to the grid with regard to keeping the voltage within a range of operating limits.\",\"PeriodicalId\":201464,\"journal\":{\"name\":\"2017 18th International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 18th International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2017.7967254\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 18th International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2017.7967254","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文的重点是在新定义的要求ENTSO-E、后续欧洲标准TS 50549和配电系统操作员通过P-Q图控制无功功率来调节电压的背景下,与连接到配电网的配电能源数量增加相关的挑战。配电网中接入和运行的配电能源数量多,导致配电网电压质量参数的变化。对测量参数的评估能够检测不符合EN 50160标准要求的过电压或电压波动。本文描述了与CEZ配电网络(DN)在中压(MV)水平并联运行的风能变流器(WEC)在规定的无功控制到功率因数的固定值和无功控制依赖于电压的情况下的电压变化过程。U、P、Q值的测量结果评估了发电厂与电网连接点电压无功功率对保持电压在一定运行限值范围内的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Regulation of the reactive power of a WEC using the ASRU application on MV level
This paper is focused on challenges related to an increased quantity of distribution energy resources connected to the distribution network within the context of newly defined requirements ENTSO-E, follow-up European standards TS 50549 and codes of distribution system operators on regulation of voltage through control of the reactive power in terms of P-Q diagram. A high number of connected and operated distribution energy resources results in changes in quality parameters of voltage in a distribution grid. The evaluation of the measured parameters enables to detect overvoltage or voltage fluctuations that are not in accordance with requirements of EN 50160 standard. This paper describes courses of voltage during operation of a wind energy converter (WEC) operated in parallel with the CEZ Distribuce distribution network (DN) on medium voltage (MV) level with the prescribed control of the reactive power to a fixed value of a power factor and the control of the reactive power depending on voltage. The measurement results of U, P, Q values evaluate an influence of the voltage reactive power in a point of connection of a power generating plant to the grid with regard to keeping the voltage within a range of operating limits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Overview of different concepts of traction drives with regard to high-speed PMSM Under frequency load shedding threats in island operation AC and DC response of heterojunction a-SiC/c-Si for PV application Features of controlled switching under normal and emergency operating conditions in medium voltage networks CFD-based evaluation of current-carrying capacity of power cables installed in free air
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1