{"title":"改良逆行气管插管通气支架技术","authors":"S. Ghoshal, A. Singam","doi":"10.5580/2af4","DOIUrl":null,"url":null,"abstract":"We report a 14-year-old, ASA grade I female who presented with a mouth opening of 5 mm. The patient complained of trismus since she was 2-years-old due to trauma to the mandible. She was diagnosed as a case of bilateral TMJ ankylosis and was posted for interpositional gap arthroplasty.Due to the unavailability of fiberoptic bronchoscope, retrograde intubation was planned. A modified technique of retrograde intubation was done, were ventilating bougie was used along with J tipped guide wire, which made the intubation easier and reduced the chances of trauma.","PeriodicalId":396781,"journal":{"name":"The Internet Journal of Anesthesiology","volume":"128 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Modified Technique Of Retrograde Intubation Using Ventilating Bougie\",\"authors\":\"S. Ghoshal, A. Singam\",\"doi\":\"10.5580/2af4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report a 14-year-old, ASA grade I female who presented with a mouth opening of 5 mm. The patient complained of trismus since she was 2-years-old due to trauma to the mandible. She was diagnosed as a case of bilateral TMJ ankylosis and was posted for interpositional gap arthroplasty.Due to the unavailability of fiberoptic bronchoscope, retrograde intubation was planned. A modified technique of retrograde intubation was done, were ventilating bougie was used along with J tipped guide wire, which made the intubation easier and reduced the chances of trauma.\",\"PeriodicalId\":396781,\"journal\":{\"name\":\"The Internet Journal of Anesthesiology\",\"volume\":\"128 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Internet Journal of Anesthesiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5580/2af4\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Internet Journal of Anesthesiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5580/2af4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Modified Technique Of Retrograde Intubation Using Ventilating Bougie
We report a 14-year-old, ASA grade I female who presented with a mouth opening of 5 mm. The patient complained of trismus since she was 2-years-old due to trauma to the mandible. She was diagnosed as a case of bilateral TMJ ankylosis and was posted for interpositional gap arthroplasty.Due to the unavailability of fiberoptic bronchoscope, retrograde intubation was planned. A modified technique of retrograde intubation was done, were ventilating bougie was used along with J tipped guide wire, which made the intubation easier and reduced the chances of trauma.