硅像素检测器电容的测量与三维仿真

L. Bosisio, F. Forti, E. Tomacruz
{"title":"硅像素检测器电容的测量与三维仿真","authors":"L. Bosisio, F. Forti, E. Tomacruz","doi":"10.1109/NSSMIC.1993.701688","DOIUrl":null,"url":null,"abstract":"We report on a study of the capacitance of silicon pixel detectors to be used as tracking devices for high energy physics experiments. The pixel capacitance matrix plays an important role in system design issues, such as preamplifier matching and cross-talk among pixels. Test results on 100 x 100 pm2 pixels are compared with data obtained from a massively parallel tridimensional simulation code which is necessary to account for the intrinsically 3D nature of the pixel structure.","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"241 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Measurement And Tridimensional Simulation Of Silicon Pixel Detector Capacitance\",\"authors\":\"L. Bosisio, F. Forti, E. Tomacruz\",\"doi\":\"10.1109/NSSMIC.1993.701688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report on a study of the capacitance of silicon pixel detectors to be used as tracking devices for high energy physics experiments. The pixel capacitance matrix plays an important role in system design issues, such as preamplifier matching and cross-talk among pixels. Test results on 100 x 100 pm2 pixels are compared with data obtained from a massively parallel tridimensional simulation code which is necessary to account for the intrinsically 3D nature of the pixel structure.\",\"PeriodicalId\":287813,\"journal\":{\"name\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"volume\":\"241 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1993.701688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.701688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文报道了用于高能物理实验跟踪装置的硅像素探测器的电容研究。像素电容矩阵在前置放大器匹配和像素间串扰等系统设计问题中起着重要的作用。将100 x 100 pm2像素上的测试结果与从大规模并行三维模拟代码获得的数据进行比较,这对于考虑像素结构的内在3D性质是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement And Tridimensional Simulation Of Silicon Pixel Detector Capacitance
We report on a study of the capacitance of silicon pixel detectors to be used as tracking devices for high energy physics experiments. The pixel capacitance matrix plays an important role in system design issues, such as preamplifier matching and cross-talk among pixels. Test results on 100 x 100 pm2 pixels are compared with data obtained from a massively parallel tridimensional simulation code which is necessary to account for the intrinsically 3D nature of the pixel structure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation Of Wavelength Shifters For Spectral Separation Of Barium Fluoride Emissions High-speed Reconstruction Of SPECT Mages With A Tailored Piecewise Neural Network A 12-channel VMEBUS-based Pulse-height Analysis Module A Bipolar Analog Front-end Integrated Circuit For The SDC Silicon Tracker Detection geometry and reconstruction error in magnetic source imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1