{"title":"基于IGBT的基本前端再生电机驱动系统分析","authors":"A. Sayed-Ahmed, R. Kerkman, B. Seibel","doi":"10.1109/APEC.2013.6520296","DOIUrl":null,"url":null,"abstract":"IGBT based Fundamental Front End “FFE” regenerative motor-drive system presents an attractive low cost solution for motor-drive applications that require regenerating power back to the grid. This technology doesn't require the addition of a breaking resistor to the drive which in many cases can present a safety hazard, and requires extra space. These motor-drive systems are extensively applied in industrial applications, as they provide an adequate replacement for standard motor-drive system applications that don't mandate reduced input current harmonics but require an economic / high power density design approach to regenerate power back to the grid. Thus, these motor-drive systems with IGBT based front-end converters have almost replaced conventional thyristor based line regenerative power converters especially in lower power applications. This paper is centered on providing a closed form solution and an in-depth mathematical analysis and performance evaluation of the IGBT based FFE.","PeriodicalId":256756,"journal":{"name":"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"37 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Analysis of IGBT based fundamental front end regenerative motor-drive systems\",\"authors\":\"A. Sayed-Ahmed, R. Kerkman, B. Seibel\",\"doi\":\"10.1109/APEC.2013.6520296\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IGBT based Fundamental Front End “FFE” regenerative motor-drive system presents an attractive low cost solution for motor-drive applications that require regenerating power back to the grid. This technology doesn't require the addition of a breaking resistor to the drive which in many cases can present a safety hazard, and requires extra space. These motor-drive systems are extensively applied in industrial applications, as they provide an adequate replacement for standard motor-drive system applications that don't mandate reduced input current harmonics but require an economic / high power density design approach to regenerate power back to the grid. Thus, these motor-drive systems with IGBT based front-end converters have almost replaced conventional thyristor based line regenerative power converters especially in lower power applications. This paper is centered on providing a closed form solution and an in-depth mathematical analysis and performance evaluation of the IGBT based FFE.\",\"PeriodicalId\":256756,\"journal\":{\"name\":\"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":\"37 2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2013.6520296\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2013.6520296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of IGBT based fundamental front end regenerative motor-drive systems
IGBT based Fundamental Front End “FFE” regenerative motor-drive system presents an attractive low cost solution for motor-drive applications that require regenerating power back to the grid. This technology doesn't require the addition of a breaking resistor to the drive which in many cases can present a safety hazard, and requires extra space. These motor-drive systems are extensively applied in industrial applications, as they provide an adequate replacement for standard motor-drive system applications that don't mandate reduced input current harmonics but require an economic / high power density design approach to regenerate power back to the grid. Thus, these motor-drive systems with IGBT based front-end converters have almost replaced conventional thyristor based line regenerative power converters especially in lower power applications. This paper is centered on providing a closed form solution and an in-depth mathematical analysis and performance evaluation of the IGBT based FFE.