{"title":"一种新的岩芯层压测试技术","authors":"C. Rickson","doi":"10.1109/EIC.1985.7458617","DOIUrl":null,"url":null,"abstract":"Engineers are now aware of the resultant insulation degradation that may be caused by stator core damage. Visual location is often simple. However a deep seated fault is not conspicuous and it is not generally appreciated that a coil burn out can be caused by shorted laminations which in turn further precipitates the iron fault.","PeriodicalId":188957,"journal":{"name":"1985 EIC 17th Electrical/Electronics Insulation Conference","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A new technique for core lamination testing\",\"authors\":\"C. Rickson\",\"doi\":\"10.1109/EIC.1985.7458617\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Engineers are now aware of the resultant insulation degradation that may be caused by stator core damage. Visual location is often simple. However a deep seated fault is not conspicuous and it is not generally appreciated that a coil burn out can be caused by shorted laminations which in turn further precipitates the iron fault.\",\"PeriodicalId\":188957,\"journal\":{\"name\":\"1985 EIC 17th Electrical/Electronics Insulation Conference\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1985 EIC 17th Electrical/Electronics Insulation Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EIC.1985.7458617\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1985 EIC 17th Electrical/Electronics Insulation Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EIC.1985.7458617","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Engineers are now aware of the resultant insulation degradation that may be caused by stator core damage. Visual location is often simple. However a deep seated fault is not conspicuous and it is not generally appreciated that a coil burn out can be caused by shorted laminations which in turn further precipitates the iron fault.