电力系统结构对Glidarc等离子体反应堆运行参数的影响

G. Komarzyniec, H. Stryczewska, P. Krupski
{"title":"电力系统结构对Glidarc等离子体反应堆运行参数的影响","authors":"G. Komarzyniec, H. Stryczewska, P. Krupski","doi":"10.1109/PPPS34859.2019.9009870","DOIUrl":null,"url":null,"abstract":"Designing power supply systems for arc plasma reactors is a complex and multi-threaded problem. Proper plasma parameters are often determined not only by electrical parameters, but also by the structural and material parameters of the power supplies. Four different types of power supply systems designed to supply a plasma reactor with a gliding arc discharge were subjected to comparative analysis. The obtained characteristics of plasma reactor operation gave information about the differences in its operation and allowed to specify the parameters of power supply systems to which special attention should be paid when it is necessary to obtain plasma with strictly specified parameters.","PeriodicalId":103240,"journal":{"name":"2019 IEEE Pulsed Power & Plasma Science (PPPS)","volume":"177 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"The Influence of the Architecture of the Power System on the Operational Parameters of the Glidarc Plasma Reactor\",\"authors\":\"G. Komarzyniec, H. Stryczewska, P. Krupski\",\"doi\":\"10.1109/PPPS34859.2019.9009870\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Designing power supply systems for arc plasma reactors is a complex and multi-threaded problem. Proper plasma parameters are often determined not only by electrical parameters, but also by the structural and material parameters of the power supplies. Four different types of power supply systems designed to supply a plasma reactor with a gliding arc discharge were subjected to comparative analysis. The obtained characteristics of plasma reactor operation gave information about the differences in its operation and allowed to specify the parameters of power supply systems to which special attention should be paid when it is necessary to obtain plasma with strictly specified parameters.\",\"PeriodicalId\":103240,\"journal\":{\"name\":\"2019 IEEE Pulsed Power & Plasma Science (PPPS)\",\"volume\":\"177 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Pulsed Power & Plasma Science (PPPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPPS34859.2019.9009870\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Pulsed Power & Plasma Science (PPPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS34859.2019.9009870","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

电弧等离子体反应器供电系统的设计是一个复杂的多线程问题。合适的等离子体参数往往不仅取决于电参数,还取决于电源的结构和材料参数。对四种不同类型的等离子体反应堆滑动电弧放电供电系统进行了对比分析。所获得的等离子体反应器运行特性提供了有关其运行差异的信息,并允许指定电源系统的参数,当需要获得具有严格规定参数的等离子体时,应特别注意这些参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Influence of the Architecture of the Power System on the Operational Parameters of the Glidarc Plasma Reactor
Designing power supply systems for arc plasma reactors is a complex and multi-threaded problem. Proper plasma parameters are often determined not only by electrical parameters, but also by the structural and material parameters of the power supplies. Four different types of power supply systems designed to supply a plasma reactor with a gliding arc discharge were subjected to comparative analysis. The obtained characteristics of plasma reactor operation gave information about the differences in its operation and allowed to specify the parameters of power supply systems to which special attention should be paid when it is necessary to obtain plasma with strictly specified parameters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Impedance Characteristics of Metal Oxide Varistor under Different Pulses Plasma Simulation and Modeling of Pseudospark Discharge for High Density and Energetic Electron Beam Generation A Comprehensive Design Procedure for High Voltage Pulse Power Transformers Concept Designs of a Compact LTD Generator with a Pulse Rise Time of 100 ns Cinco: A Compact High-Current Driver for High-Energy-Density Physics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1