最近的DIII-D中性束校准结果

J. Wight, R. Hong, J. Phillips
{"title":"最近的DIII-D中性束校准结果","authors":"J. Wight, R. Hong, J. Phillips","doi":"10.1109/FUSION.1991.218824","DOIUrl":null,"url":null,"abstract":"The fundamental parameters by which injected DIII-D neutral beam power is calculated have all been recently measured using waterflow calorimetry and target tile thermocouples. The measured neutralization efficiency is 66%, close to the modeled equilibrium value of 70% for a 75 kV deuterium beam. Waterflow calorimetry has proven to be a useful tool to measure the neutralization efficiency, contrary to earlier results. The beamline transmission efficiency has been measured for each beam independently, and averages about 78% among the beams. Finally, the drift duct reionization survival rate is 95%. By making use of the independence of preshot target tile temperature and duct reionization, interpretation of thermocouple data has yielded more accurate results.<<ETX>>","PeriodicalId":318951,"journal":{"name":"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Recent DIII-D neutral beam calibration results\",\"authors\":\"J. Wight, R. Hong, J. Phillips\",\"doi\":\"10.1109/FUSION.1991.218824\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The fundamental parameters by which injected DIII-D neutral beam power is calculated have all been recently measured using waterflow calorimetry and target tile thermocouples. The measured neutralization efficiency is 66%, close to the modeled equilibrium value of 70% for a 75 kV deuterium beam. Waterflow calorimetry has proven to be a useful tool to measure the neutralization efficiency, contrary to earlier results. The beamline transmission efficiency has been measured for each beam independently, and averages about 78% among the beams. Finally, the drift duct reionization survival rate is 95%. By making use of the independence of preshot target tile temperature and duct reionization, interpretation of thermocouple data has yielded more accurate results.<<ETX>>\",\"PeriodicalId\":318951,\"journal\":{\"name\":\"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUSION.1991.218824\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[Proceedings] The 14th IEEE/NPSS Symposium Fusion Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUSION.1991.218824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

计算注入DIII-D中性束功率的基本参数最近都是用水流量热法和靶瓦热电偶测量的。实测中和效率为66%,接近75 kV氘束流70%的模型平衡值。与早期的结果相反,水流量热法已被证明是测量中和效率的有用工具。对各光束的光束线传输效率进行了独立测量,平均传输效率约为78%。最后,漂移管再电离存活率为95%。利用预射靶瓦温度和管道再电离的独立性,热电偶数据的解释得到了更准确的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Recent DIII-D neutral beam calibration results
The fundamental parameters by which injected DIII-D neutral beam power is calculated have all been recently measured using waterflow calorimetry and target tile thermocouples. The measured neutralization efficiency is 66%, close to the modeled equilibrium value of 70% for a 75 kV deuterium beam. Waterflow calorimetry has proven to be a useful tool to measure the neutralization efficiency, contrary to earlier results. The beamline transmission efficiency has been measured for each beam independently, and averages about 78% among the beams. Finally, the drift duct reionization survival rate is 95%. By making use of the independence of preshot target tile temperature and duct reionization, interpretation of thermocouple data has yielded more accurate results.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of a coil to correct magnetic field errors on the DIII-D tokamak The charge exchange recombination diagnostic system on the DIII-D tokamak Software upgrade for the DIII-D neutral beam control systems Timing system for neutral beam injection on the DIII-D tokamak DIII-D radiation shielding procedures and experiences
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1