{"title":"中压电机驱动压缩机继电保护整定计算的特殊性","authors":"S. Omar, Daniel Dobrilov","doi":"10.1109/BulEF56479.2022.10021180","DOIUrl":null,"url":null,"abstract":"A new approach of tripping single-phase faults in networks with an isolated star center to preserve the operation of compressors in the event of a fault is considered. A solution was found for tripping compressors by the protection relay in case of external damage to the plant's power supply network.","PeriodicalId":375606,"journal":{"name":"2022 14th Electrical Engineering Faculty Conference (BulEF)","volume":"142 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Particularities in the calculation of the relay protection settings of MV motors driving compressors\",\"authors\":\"S. Omar, Daniel Dobrilov\",\"doi\":\"10.1109/BulEF56479.2022.10021180\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new approach of tripping single-phase faults in networks with an isolated star center to preserve the operation of compressors in the event of a fault is considered. A solution was found for tripping compressors by the protection relay in case of external damage to the plant's power supply network.\",\"PeriodicalId\":375606,\"journal\":{\"name\":\"2022 14th Electrical Engineering Faculty Conference (BulEF)\",\"volume\":\"142 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-09-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 14th Electrical Engineering Faculty Conference (BulEF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BulEF56479.2022.10021180\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 14th Electrical Engineering Faculty Conference (BulEF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BulEF56479.2022.10021180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Particularities in the calculation of the relay protection settings of MV motors driving compressors
A new approach of tripping single-phase faults in networks with an isolated star center to preserve the operation of compressors in the event of a fault is considered. A solution was found for tripping compressors by the protection relay in case of external damage to the plant's power supply network.