与蒙特卡洛仿真同源和异同同剂量的分布分析

Sitti Yani
{"title":"与蒙特卡洛仿真同源和异同同剂量的分布分析","authors":"Sitti Yani","doi":"10.31258/jkfi.19.1.39-44","DOIUrl":null,"url":null,"abstract":"Monte Carlo simulation with electron gamma shower (EGSnrc) code can produce 3-dimensional dose distribution data. The percent depth dose curve (PDD), dose profile, and isodose curve can be extracted through this 3-dimensional data. In this study, a photon source with an energy of 2 MeV is placed at the source to surface distance (SSD) from the phantom surface by adjusting the collimator aperture which is used to control the size of the exposure field. The SSD distance was varied at a distance of 50 cm, 70 cm, 80 cm, 90 cm, and 100 cm. The size of the exposure area is also varied by 2 × 2 cm 2 , 5 × 5 cm 2 , 7 × 7 cm 2 , and 10 × 10 cm 2 . The dose distribution analysis was carried out on homogeneous phantoms containing water and inhomogeneous phantoms containing tissue/bone/lung/bone/tissue material. The PDD curve and dose profile represent dose changes with depth and x or y direction, respectively. The PDD curve on a homogeneous phantom shows an increase in the value on the surface of the phantom to the depth with the maximum dose. This curve then decreases gradually with increasing depth. Inhomogeneous ghosts show spikes in the border region of the two media with different densities. This is due to the contribution of the backscattered electrons generated by the bone media and into the tissue media. This phenomenon is also seen in the isodose curve for inhomogeneous phantoms.","PeriodicalId":403286,"journal":{"name":"Komunikasi Fisika Indonesia","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"ANALISA DISTRIBUSI DOSIS PADA FANTOM HOMOGEN DAN INHOMOGEN DENGAN SIMULASI MONTE CARLO\",\"authors\":\"Sitti Yani\",\"doi\":\"10.31258/jkfi.19.1.39-44\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Monte Carlo simulation with electron gamma shower (EGSnrc) code can produce 3-dimensional dose distribution data. The percent depth dose curve (PDD), dose profile, and isodose curve can be extracted through this 3-dimensional data. In this study, a photon source with an energy of 2 MeV is placed at the source to surface distance (SSD) from the phantom surface by adjusting the collimator aperture which is used to control the size of the exposure field. The SSD distance was varied at a distance of 50 cm, 70 cm, 80 cm, 90 cm, and 100 cm. The size of the exposure area is also varied by 2 × 2 cm 2 , 5 × 5 cm 2 , 7 × 7 cm 2 , and 10 × 10 cm 2 . The dose distribution analysis was carried out on homogeneous phantoms containing water and inhomogeneous phantoms containing tissue/bone/lung/bone/tissue material. The PDD curve and dose profile represent dose changes with depth and x or y direction, respectively. The PDD curve on a homogeneous phantom shows an increase in the value on the surface of the phantom to the depth with the maximum dose. This curve then decreases gradually with increasing depth. Inhomogeneous ghosts show spikes in the border region of the two media with different densities. This is due to the contribution of the backscattered electrons generated by the bone media and into the tissue media. This phenomenon is also seen in the isodose curve for inhomogeneous phantoms.\",\"PeriodicalId\":403286,\"journal\":{\"name\":\"Komunikasi Fisika Indonesia\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Komunikasi Fisika Indonesia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31258/jkfi.19.1.39-44\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Komunikasi Fisika Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31258/jkfi.19.1.39-44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用电子伽玛阵雨(EGSnrc)程序进行蒙特卡罗模拟可以得到三维剂量分布数据。通过该三维数据可以提取出百分比深度剂量曲线(PDD)、剂量剖面和等剂量曲线。在本研究中,通过调节准直器孔径来控制曝光场的大小,将能量为2 MeV的光子源放置在离幻影表面的源面距离(SSD)处。SSD距离分别为50 cm、70 cm、80 cm、90 cm、100 cm。曝光区域的大小也随2 × 2 cm 2、5 × 5 cm 2、7 × 7 cm 2和10 × 10 cm 2而变化。对含水的均质模型和含组织/骨/肺/骨/组织材料的非均质模型进行剂量分布分析。PDD曲线和剂量曲线分别表示剂量随深度和x或y方向的变化。均匀模体上的PDD曲线显示,模体表面的值随着最大剂量的增加而增加。该曲线随着深度的增加而逐渐减小。非均匀鬼在密度不同的两种介质的边界区域呈现出尖峰。这是由于骨介质和组织介质产生的背散射电子的贡献。这种现象也见于非均匀幻像的等剂量曲线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ANALISA DISTRIBUSI DOSIS PADA FANTOM HOMOGEN DAN INHOMOGEN DENGAN SIMULASI MONTE CARLO
Monte Carlo simulation with electron gamma shower (EGSnrc) code can produce 3-dimensional dose distribution data. The percent depth dose curve (PDD), dose profile, and isodose curve can be extracted through this 3-dimensional data. In this study, a photon source with an energy of 2 MeV is placed at the source to surface distance (SSD) from the phantom surface by adjusting the collimator aperture which is used to control the size of the exposure field. The SSD distance was varied at a distance of 50 cm, 70 cm, 80 cm, 90 cm, and 100 cm. The size of the exposure area is also varied by 2 × 2 cm 2 , 5 × 5 cm 2 , 7 × 7 cm 2 , and 10 × 10 cm 2 . The dose distribution analysis was carried out on homogeneous phantoms containing water and inhomogeneous phantoms containing tissue/bone/lung/bone/tissue material. The PDD curve and dose profile represent dose changes with depth and x or y direction, respectively. The PDD curve on a homogeneous phantom shows an increase in the value on the surface of the phantom to the depth with the maximum dose. This curve then decreases gradually with increasing depth. Inhomogeneous ghosts show spikes in the border region of the two media with different densities. This is due to the contribution of the backscattered electrons generated by the bone media and into the tissue media. This phenomenon is also seen in the isodose curve for inhomogeneous phantoms.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
AKTIVASI ZEOLIT ALAM SEBAGAI ADSORBEN PEWARNA ALAMI KULIT BUAH NAGA (PITAYA) ANALISIS HASIL KALIBRASI ALAT PHOTOTHERAPY MERK GEA MEDICAL TYPE XHZ-90 FABRIKASI ELEKTRODA KARBON DARI SABUT KELAPA MUDA DENGAN AKTIVASI FISIKA SEBAGAI APLIKASI SUPERKAPASITOR PENGARUH DOPING MANGAN TERHADAP KOMPOSISI DAN SIFAT KRISTALINITAS PARTIKEL OKSIDA BESI PASIR ALAM SUNGAI ROKAN DIPREPARASI DENGAN METODE BALL MILLING APLIKASI UJI COBA SKALA LABORATORIUM IMPLEMENTASI PROTOTYPE ALAT INOVASI TEKNOLOGI PASCA PANEN BERBASIS BIOMASSA UNTUK DETEKSI TEMPERATURE DENGAN SISTEM INTERNET OF THINGS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1