{"title":"双向车辆对栅格谐振变换器电池充电器非相称性能目标的探讨","authors":"Kuseso Onai, O. Ojo","doi":"10.1109/SPEC52827.2021.9709475","DOIUrl":null,"url":null,"abstract":"In bidirectional Wireless power transfer (BDWPT) for electric vehicle battery chargers, aside improving efficiency, the effects of stray magnetic field on users and the general public is also of concern. Hence, the stray magnetic field and power loss are key performance indicators to be optimized. The optimization, reported in literature, is obtained with Pareto front which is derived by sweeping the physical parameters of the coil. This optimization is realized at the design stage. This work explores the optimization of these performance indicators from the control point of view and can be achieved on-line. The method discussed here involves the control of the duty cycle and displacement angles of the inverter and rectifier voltages to meet the objective of reducing the stray field and power losses. To this end, the classical Lagrange optimization procedure is employed to simultaneously minimize the stray magnetic field and power loss for a given output power condition.","PeriodicalId":236251,"journal":{"name":"2021 IEEE Southern Power Electronics Conference (SPEC)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exploration of The Non – Commensurate Performance Objectives of Bi – Directional Vehicle to Grid Resonant Converter Based Battery Charger\",\"authors\":\"Kuseso Onai, O. Ojo\",\"doi\":\"10.1109/SPEC52827.2021.9709475\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In bidirectional Wireless power transfer (BDWPT) for electric vehicle battery chargers, aside improving efficiency, the effects of stray magnetic field on users and the general public is also of concern. Hence, the stray magnetic field and power loss are key performance indicators to be optimized. The optimization, reported in literature, is obtained with Pareto front which is derived by sweeping the physical parameters of the coil. This optimization is realized at the design stage. This work explores the optimization of these performance indicators from the control point of view and can be achieved on-line. The method discussed here involves the control of the duty cycle and displacement angles of the inverter and rectifier voltages to meet the objective of reducing the stray field and power losses. To this end, the classical Lagrange optimization procedure is employed to simultaneously minimize the stray magnetic field and power loss for a given output power condition.\",\"PeriodicalId\":236251,\"journal\":{\"name\":\"2021 IEEE Southern Power Electronics Conference (SPEC)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Southern Power Electronics Conference (SPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SPEC52827.2021.9709475\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Southern Power Electronics Conference (SPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEC52827.2021.9709475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Exploration of The Non – Commensurate Performance Objectives of Bi – Directional Vehicle to Grid Resonant Converter Based Battery Charger
In bidirectional Wireless power transfer (BDWPT) for electric vehicle battery chargers, aside improving efficiency, the effects of stray magnetic field on users and the general public is also of concern. Hence, the stray magnetic field and power loss are key performance indicators to be optimized. The optimization, reported in literature, is obtained with Pareto front which is derived by sweeping the physical parameters of the coil. This optimization is realized at the design stage. This work explores the optimization of these performance indicators from the control point of view and can be achieved on-line. The method discussed here involves the control of the duty cycle and displacement angles of the inverter and rectifier voltages to meet the objective of reducing the stray field and power losses. To this end, the classical Lagrange optimization procedure is employed to simultaneously minimize the stray magnetic field and power loss for a given output power condition.