{"title":"提出了一种基于动态仿真的减载和负荷恢复实现策略","authors":"I.N. Perumal, C. C. Ying","doi":"10.1109/PECON.2004.1461640","DOIUrl":null,"url":null,"abstract":"Electric load shedding is implemented to maintain the generation power margin at nominated level when load demand is higher than electric supply. This prevents the widespread system collapse when a fault occurs. The scope of study consists of system analysis, design and simulation. Dynamic simulations are performed using the ERACS power analysis software. When the frequency falls below preset level at a certain rate, a predetermined amount of load will be removed to restore the system frequency. Important design considerations for this scheme are the maximum anticipated overload, number of load shedding steps, size of load shed at each step and frequency relay settings. Load restoration after load shedding can only be executed after the system has recovered completely and its normal frequency is restored. Loads should be restored in small blocks sequenced by time delay between successive restorations to allow frequency stabilization. A case study is carried out on PETRONAS Penapisan Melaka, whereby a load shedding scheme is designed for its upcoming cogeneration plant. Dynamic simulations performed indicate that the load shedding design is feasible and able to halt frequency collapse due to generation loss. The design strategy, calculations and justification are presented in this paper.","PeriodicalId":375856,"journal":{"name":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2004-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"A proposed strategy of implementation for load shedding and load recovery with dynamic simulations\",\"authors\":\"I.N. Perumal, C. C. Ying\",\"doi\":\"10.1109/PECON.2004.1461640\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electric load shedding is implemented to maintain the generation power margin at nominated level when load demand is higher than electric supply. This prevents the widespread system collapse when a fault occurs. The scope of study consists of system analysis, design and simulation. Dynamic simulations are performed using the ERACS power analysis software. When the frequency falls below preset level at a certain rate, a predetermined amount of load will be removed to restore the system frequency. Important design considerations for this scheme are the maximum anticipated overload, number of load shedding steps, size of load shed at each step and frequency relay settings. Load restoration after load shedding can only be executed after the system has recovered completely and its normal frequency is restored. Loads should be restored in small blocks sequenced by time delay between successive restorations to allow frequency stabilization. A case study is carried out on PETRONAS Penapisan Melaka, whereby a load shedding scheme is designed for its upcoming cogeneration plant. Dynamic simulations performed indicate that the load shedding design is feasible and able to halt frequency collapse due to generation loss. The design strategy, calculations and justification are presented in this paper.\",\"PeriodicalId\":375856,\"journal\":{\"name\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PECon 2004. Proceedings. National Power and Energy Conference, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PECON.2004.1461640\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PECon 2004. Proceedings. National Power and Energy Conference, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2004.1461640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

摘要

当负荷需求高于电力供应时,电力减载是为了将发电余量维持在指定水平。这可以防止在发生故障时广泛的系统崩溃。研究范围包括系统分析、设计和仿真。采用ERACS功率分析软件进行了动态仿真。当频率以一定的速率下降到预设的水平以下时,将移除预定数量的负载以恢复系统频率。该方案的重要设计考虑因素是最大预期过载、减载步骤数、每一步减载的大小和频率继电器设置。只有当系统完全恢复正常工作频率后,才能执行减载后恢复负载操作。负载应按连续恢复之间的时间延迟进行小块恢复,以实现频率稳定。马来西亚国家石油公司Penapisan马六甲进行了一个案例研究,其中为其即将到来的热电联产工厂设计了一个减载方案。动态仿真结果表明,该减载设计是可行的,能够有效抑制因发电损耗引起的频率崩溃。本文给出了设计策略、计算和论证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A proposed strategy of implementation for load shedding and load recovery with dynamic simulations
Electric load shedding is implemented to maintain the generation power margin at nominated level when load demand is higher than electric supply. This prevents the widespread system collapse when a fault occurs. The scope of study consists of system analysis, design and simulation. Dynamic simulations are performed using the ERACS power analysis software. When the frequency falls below preset level at a certain rate, a predetermined amount of load will be removed to restore the system frequency. Important design considerations for this scheme are the maximum anticipated overload, number of load shedding steps, size of load shed at each step and frequency relay settings. Load restoration after load shedding can only be executed after the system has recovered completely and its normal frequency is restored. Loads should be restored in small blocks sequenced by time delay between successive restorations to allow frequency stabilization. A case study is carried out on PETRONAS Penapisan Melaka, whereby a load shedding scheme is designed for its upcoming cogeneration plant. Dynamic simulations performed indicate that the load shedding design is feasible and able to halt frequency collapse due to generation loss. The design strategy, calculations and justification are presented in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of improved genetic algorithms for loss minimisation in power system Implementation of different passive filter designs for harmonic mitigation A new single-phase two-wire hybrid active power filter using extension p-q theorem for photovoltaic application Voltage stability based weak area clustering technique in power system Calculation of static thrust on a linear DC actuator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1