{"title":"辐照距离对闪烁体测量管电压和x射线器件时间的影响","authors":"All Adin Nurhuda, M. R. Mak'ruf, T. Indrato, Sari Luthfiyah","doi":"10.35882/jeeemi.v4i2.7","DOIUrl":null,"url":null,"abstract":"The results of the output of the X-ray device are very important to know how much the correct value, whether it is in accordance with the arrangements made by radiology personnel or there is a difference even deviation of the value out of the arrangement. This conformity test activity needs a testing tool that is often used by BAPETEN personnel to find out how much the output value of KV, Time, Dose, Room leak, mA and mAs from an X-ray device unit. The purpose of this study was to analyze the effect of irradiation distance on tube voltage measurements and X-ray device time using Scintillators. The study used scintillator sensors to detect radiation, arduino as a programming source, bluetooth HC-05 as digital communication between hardware and PC, PC / Delphi as display. This research design is Pre-Experimental with After Only Design research type. Where the author takes data compared to standard tools then analyzes the data. The results showed the largest error at a distance of 120cm with a 90 KV setting of 43.52%. And the smallest error is at a distance of 120cm with a 50 KV setting of 0.07%.","PeriodicalId":369032,"journal":{"name":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Irradiation Distance on Tube Voltage Measurement and X-Ray Device Time Using Scintillator\",\"authors\":\"All Adin Nurhuda, M. R. Mak'ruf, T. Indrato, Sari Luthfiyah\",\"doi\":\"10.35882/jeeemi.v4i2.7\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results of the output of the X-ray device are very important to know how much the correct value, whether it is in accordance with the arrangements made by radiology personnel or there is a difference even deviation of the value out of the arrangement. This conformity test activity needs a testing tool that is often used by BAPETEN personnel to find out how much the output value of KV, Time, Dose, Room leak, mA and mAs from an X-ray device unit. The purpose of this study was to analyze the effect of irradiation distance on tube voltage measurements and X-ray device time using Scintillators. The study used scintillator sensors to detect radiation, arduino as a programming source, bluetooth HC-05 as digital communication between hardware and PC, PC / Delphi as display. This research design is Pre-Experimental with After Only Design research type. Where the author takes data compared to standard tools then analyzes the data. The results showed the largest error at a distance of 120cm with a 90 KV setting of 43.52%. And the smallest error is at a distance of 120cm with a 50 KV setting of 0.07%.\",\"PeriodicalId\":369032,\"journal\":{\"name\":\"Journal of Electronics, Electromedical Engineering, and Medical Informatics\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Electronics, Electromedical Engineering, and Medical Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35882/jeeemi.v4i2.7\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics, Electromedical Engineering, and Medical Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35882/jeeemi.v4i2.7","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of Irradiation Distance on Tube Voltage Measurement and X-Ray Device Time Using Scintillator
The results of the output of the X-ray device are very important to know how much the correct value, whether it is in accordance with the arrangements made by radiology personnel or there is a difference even deviation of the value out of the arrangement. This conformity test activity needs a testing tool that is often used by BAPETEN personnel to find out how much the output value of KV, Time, Dose, Room leak, mA and mAs from an X-ray device unit. The purpose of this study was to analyze the effect of irradiation distance on tube voltage measurements and X-ray device time using Scintillators. The study used scintillator sensors to detect radiation, arduino as a programming source, bluetooth HC-05 as digital communication between hardware and PC, PC / Delphi as display. This research design is Pre-Experimental with After Only Design research type. Where the author takes data compared to standard tools then analyzes the data. The results showed the largest error at a distance of 120cm with a 90 KV setting of 43.52%. And the smallest error is at a distance of 120cm with a 50 KV setting of 0.07%.