中剂量水平下用于伽马射线剂量测定的玫瑰色染料萃取液的液态放射性致色剂

Indah Nursyamsi Handayani, C. Imawan
{"title":"中剂量水平下用于伽马射线剂量测定的玫瑰色染料萃取液的液态放射性致色剂","authors":"Indah Nursyamsi Handayani, C. Imawan","doi":"10.1109/ISSIMM.2018.8727740","DOIUrl":null,"url":null,"abstract":"The food sterilization process with the gamma irradiation technique is highly determined by the accuracy of the absorbed dose. One of the absorbed dose measurement systems that can be used to monitor food irradiation processes is radiochromic dosimeter. So, the application of radiochromic dosimeter in the food irradiation is very necessary. This paper reports a simple dosimetry system using liquid radiochromic. The liquid dosimeter dye was prepared from Hibiscus sabdariffa L. (Roselle) dried flower extract using the maceration method in ethanol solution. The dosimeter was tested using gamma ray from a Cobalt-60 source at the medium dose level from 1 to 10 kGy. The color of the dye fades from red to clear gradually with an increasing dose of gamma irradiation. UV-visible characterization shows that the dye solution has an absorption peak at 530 nm. This peak absorption value decreases as the dose of irradiation increases. The stability of unirradiated and irradiated liquid radiochromic dosimeters has been observed for 30 days and shows good stability. These results indicate that liquid radiochromic can be applied as a routine dosimeter for the treatment of food irradiation at the medium dose level.","PeriodicalId":178365,"journal":{"name":"2018 3rd International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Liquid Radiochromic from Roselle Dye Extract for Gamma-ray Dosimetry Applications at Medium Dose Levels\",\"authors\":\"Indah Nursyamsi Handayani, C. Imawan\",\"doi\":\"10.1109/ISSIMM.2018.8727740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The food sterilization process with the gamma irradiation technique is highly determined by the accuracy of the absorbed dose. One of the absorbed dose measurement systems that can be used to monitor food irradiation processes is radiochromic dosimeter. So, the application of radiochromic dosimeter in the food irradiation is very necessary. This paper reports a simple dosimetry system using liquid radiochromic. The liquid dosimeter dye was prepared from Hibiscus sabdariffa L. (Roselle) dried flower extract using the maceration method in ethanol solution. The dosimeter was tested using gamma ray from a Cobalt-60 source at the medium dose level from 1 to 10 kGy. The color of the dye fades from red to clear gradually with an increasing dose of gamma irradiation. UV-visible characterization shows that the dye solution has an absorption peak at 530 nm. This peak absorption value decreases as the dose of irradiation increases. The stability of unirradiated and irradiated liquid radiochromic dosimeters has been observed for 30 days and shows good stability. These results indicate that liquid radiochromic can be applied as a routine dosimeter for the treatment of food irradiation at the medium dose level.\",\"PeriodicalId\":178365,\"journal\":{\"name\":\"2018 3rd International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 3rd International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISSIMM.2018.8727740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 3rd International Seminar on Sensors, Instrumentation, Measurement and Metrology (ISSIMM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSIMM.2018.8727740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

食品辐照灭菌过程在很大程度上取决于吸收剂量的准确性。可用于监测食品辐照过程的吸收剂量测量系统之一是放射性致色剂量计。因此,放射性致色剂量计在食品辐照中的应用是十分必要的。本文报道了一种简单的液体放射性致色剂剂量测定系统。以芙蓉干花提取物为原料,采用乙醇浸渍法制备液体剂量计染料。使用来自钴-60源的伽马射线,在1至10千戈瑞的中等剂量水平上对剂量计进行了测试。随着伽马射线照射剂量的增加,染料的颜色逐渐从红色变清。紫外可见表征表明,该染料溶液在530 nm处有一个吸收峰。该峰值吸收值随着辐照剂量的增加而减小。对未辐照和辐照的液体放射性铬剂量计进行了30天的稳定性观察,显示出良好的稳定性。这些结果表明,液体放射性致色剂可作为常规剂量计用于中等剂量水平的食品辐照处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Liquid Radiochromic from Roselle Dye Extract for Gamma-ray Dosimetry Applications at Medium Dose Levels
The food sterilization process with the gamma irradiation technique is highly determined by the accuracy of the absorbed dose. One of the absorbed dose measurement systems that can be used to monitor food irradiation processes is radiochromic dosimeter. So, the application of radiochromic dosimeter in the food irradiation is very necessary. This paper reports a simple dosimetry system using liquid radiochromic. The liquid dosimeter dye was prepared from Hibiscus sabdariffa L. (Roselle) dried flower extract using the maceration method in ethanol solution. The dosimeter was tested using gamma ray from a Cobalt-60 source at the medium dose level from 1 to 10 kGy. The color of the dye fades from red to clear gradually with an increasing dose of gamma irradiation. UV-visible characterization shows that the dye solution has an absorption peak at 530 nm. This peak absorption value decreases as the dose of irradiation increases. The stability of unirradiated and irradiated liquid radiochromic dosimeters has been observed for 30 days and shows good stability. These results indicate that liquid radiochromic can be applied as a routine dosimeter for the treatment of food irradiation at the medium dose level.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design and Manufacturing of Motor-Tendon Actuator for a Soft Starfish-Like Robot Gray Scale and Edge Detecting Method To Extract Raw Data in The Diffusivity Measurement System Omnidirectional Sensing for Escaping Local Minimum on Potential Field Mobile Robot Path Planning in Corridors Environment Enhancing Temperature Sensitivity for The SMS Fiber Structure Temperature Sensor Copyright
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1