基于双孔椭圆芯光纤的螺旋长周期光栅折射率传感器

Chao Liu, Yu Zhang, Zhihai Liu, Yaxun Zhang
{"title":"基于双孔椭圆芯光纤的螺旋长周期光栅折射率传感器","authors":"Chao Liu, Yu Zhang, Zhihai Liu, Yaxun Zhang","doi":"10.1117/12.2267548","DOIUrl":null,"url":null,"abstract":"In this paper, the fabrication of a novel refractive index sensor based on helical long period grating (HLPG) written in a dual-hole elliptical core fiber (DHECF) was demonstrated and the sensing characteristic was experimentally investigated. Due to the structure of the DHECF, The proposed HLPG sensor could work with ultra-small dose testing samples. In addition, since the sample is isolated from the external environment, the testing is immunity to the external interference. The experimental results showed that the testing sensitivity of the sensor was 194nm/RIU with the refractive index range of 1.333 to 1.385. The proposed structure will have a good practicability in the microfluidic sensing system.","PeriodicalId":198716,"journal":{"name":"2017 25th Optical Fiber Sensors Conference (OFS)","volume":"806 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Refractive index sensor based on helical long period grating based on dual-hole elliptical core fiber\",\"authors\":\"Chao Liu, Yu Zhang, Zhihai Liu, Yaxun Zhang\",\"doi\":\"10.1117/12.2267548\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the fabrication of a novel refractive index sensor based on helical long period grating (HLPG) written in a dual-hole elliptical core fiber (DHECF) was demonstrated and the sensing characteristic was experimentally investigated. Due to the structure of the DHECF, The proposed HLPG sensor could work with ultra-small dose testing samples. In addition, since the sample is isolated from the external environment, the testing is immunity to the external interference. The experimental results showed that the testing sensitivity of the sensor was 194nm/RIU with the refractive index range of 1.333 to 1.385. The proposed structure will have a good practicability in the microfluidic sensing system.\",\"PeriodicalId\":198716,\"journal\":{\"name\":\"2017 25th Optical Fiber Sensors Conference (OFS)\",\"volume\":\"806 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 25th Optical Fiber Sensors Conference (OFS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2267548\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 25th Optical Fiber Sensors Conference (OFS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2267548","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了一种基于双孔椭圆芯光纤(DHECF)的螺旋长周期光栅(HLPG)的折射率传感器的制作方法,并对其传感特性进行了实验研究。由于DHECF的结构,所提出的HLPG传感器可以用于超小剂量的测试样品。此外,由于样品与外界环境隔离,因此测试对外界干扰具有免疫力。实验结果表明,该传感器的测试灵敏度为194nm/RIU,折射率范围为1.333 ~ 1.385。该结构在微流控传感系统中具有较好的实用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Refractive index sensor based on helical long period grating based on dual-hole elliptical core fiber
In this paper, the fabrication of a novel refractive index sensor based on helical long period grating (HLPG) written in a dual-hole elliptical core fiber (DHECF) was demonstrated and the sensing characteristic was experimentally investigated. Due to the structure of the DHECF, The proposed HLPG sensor could work with ultra-small dose testing samples. In addition, since the sample is isolated from the external environment, the testing is immunity to the external interference. The experimental results showed that the testing sensitivity of the sensor was 194nm/RIU with the refractive index range of 1.333 to 1.385. The proposed structure will have a good practicability in the microfluidic sensing system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Multi-parameter measurements using optical fibre long period gratings for indoor air quality monitoring Impact of the laser phase noise on chirped-pulse phase-sensitive OTDR Strain and temperature measurement using a 9.5-m continuous chirped fiber Bragg grating with millimeter resolution Fiber optic nickel ion sensor based on direct ligand immobilization Eliminating the non-local effect in frequency-fixed probe wave based BOTDA sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1