高频神经电刺激时稳态膜电位和钠电流的变化

Lifei Sun, Hailong Liu
{"title":"高频神经电刺激时稳态膜电位和钠电流的变化","authors":"Lifei Sun, Hailong Liu","doi":"10.1109/ICMTMA.2015.245","DOIUrl":null,"url":null,"abstract":"Nerve injuries found in previous studies need to be explained with appropriate simulation studies. This study employed an axonal model based on the Frankenhaeuser-Huxley (FH) equations to investigate the changes of membrane potentials and sodium currents during high frequency (HF) electrical stimulation. The HF electrical stimulation induced continuously changing high-amplitude membrane responses different from the normal action potentials (APs). The phenomena of steady state depolarization and hyper polarization were observed at relatively low (1 kHz) and high (10 kHz) frequency HF currents respectively, for which overall inward and outward sodium fluxes occurred. Although only inward sodium flux occurred at low amplitude (1 mA) HF current, both inward and outward sodium fluxes were observed at high amplitude (5 mA) HF current. Higher frequencies (10 kHz) of HF currents caused more inward sodium fluxes and had bigger inward-to-outward ratio values. The results suggested the existence of an optimal HF frequency for HF electrical nerve stimulation. Successful verification of this would promote the design of safe HF electrical nerve stimulation protocols.","PeriodicalId":196962,"journal":{"name":"2015 Seventh International Conference on Measuring Technology and Mechatronics Automation","volume":"103 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Steady State Membrane Potential and Sodium Current Changes during High Frequency Electrical Nerve Stimulation\",\"authors\":\"Lifei Sun, Hailong Liu\",\"doi\":\"10.1109/ICMTMA.2015.245\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Nerve injuries found in previous studies need to be explained with appropriate simulation studies. This study employed an axonal model based on the Frankenhaeuser-Huxley (FH) equations to investigate the changes of membrane potentials and sodium currents during high frequency (HF) electrical stimulation. The HF electrical stimulation induced continuously changing high-amplitude membrane responses different from the normal action potentials (APs). The phenomena of steady state depolarization and hyper polarization were observed at relatively low (1 kHz) and high (10 kHz) frequency HF currents respectively, for which overall inward and outward sodium fluxes occurred. Although only inward sodium flux occurred at low amplitude (1 mA) HF current, both inward and outward sodium fluxes were observed at high amplitude (5 mA) HF current. Higher frequencies (10 kHz) of HF currents caused more inward sodium fluxes and had bigger inward-to-outward ratio values. The results suggested the existence of an optimal HF frequency for HF electrical nerve stimulation. Successful verification of this would promote the design of safe HF electrical nerve stimulation protocols.\",\"PeriodicalId\":196962,\"journal\":{\"name\":\"2015 Seventh International Conference on Measuring Technology and Mechatronics Automation\",\"volume\":\"103 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Seventh International Conference on Measuring Technology and Mechatronics Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICMTMA.2015.245\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Seventh International Conference on Measuring Technology and Mechatronics Automation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMTMA.2015.245","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在以往的研究中发现的神经损伤需要通过适当的模拟研究来解释。本研究采用基于Frankenhaeuser-Huxley (FH)方程的轴突模型,研究了高频电刺激下膜电位和钠电流的变化。高频电刺激诱导了不同于正常动作电位(APs)的持续变化的高振幅膜反应。在相对较低(1 kHz)和较高(10 kHz)频率的高频电流下,分别观察到稳态退极化和超极化现象,钠通量总体向内和向外。虽然在低幅值(1 mA)高频电流下只发生向内的钠通量,但在高幅值(5 mA)高频电流下均观察到向内和向外的钠通量。高频电流频率越高(10 kHz),向内的钠通量越大,向内与向外的比值越大。结果提示,高频神经电刺激存在一个最佳高频频率。成功的验证将促进高频神经电刺激方案的设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Steady State Membrane Potential and Sodium Current Changes during High Frequency Electrical Nerve Stimulation
Nerve injuries found in previous studies need to be explained with appropriate simulation studies. This study employed an axonal model based on the Frankenhaeuser-Huxley (FH) equations to investigate the changes of membrane potentials and sodium currents during high frequency (HF) electrical stimulation. The HF electrical stimulation induced continuously changing high-amplitude membrane responses different from the normal action potentials (APs). The phenomena of steady state depolarization and hyper polarization were observed at relatively low (1 kHz) and high (10 kHz) frequency HF currents respectively, for which overall inward and outward sodium fluxes occurred. Although only inward sodium flux occurred at low amplitude (1 mA) HF current, both inward and outward sodium fluxes were observed at high amplitude (5 mA) HF current. Higher frequencies (10 kHz) of HF currents caused more inward sodium fluxes and had bigger inward-to-outward ratio values. The results suggested the existence of an optimal HF frequency for HF electrical nerve stimulation. Successful verification of this would promote the design of safe HF electrical nerve stimulation protocols.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Based on Data Analysis about Risks of Bidding Decisions in Engineering Projects Study on Trusted Vitual Machine Platform Based on Cipher Card Meso-Structure Quantitative Research about Coals Based on the Digital Image Processing Technology News of Atomic Events Time Sequence Relationship Recognition Based on Function Word and Predicate Co-occurrence Research on Bridge Subsidence Control Based on Slip Casting Control
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1