有源电力滤波器的改进磁滞电流控制

X. Dianguo, Guo Jianjun, Liu Hankui, Gong Maozhong
{"title":"有源电力滤波器的改进磁滞电流控制","authors":"X. Dianguo, Guo Jianjun, Liu Hankui, Gong Maozhong","doi":"10.1109/ISIE.2003.1267929","DOIUrl":null,"url":null,"abstract":"This paper presents an improved hysteresis current control to enhance the performance of current tracking control for active power filter while reduce the number of switching. This control technique utilizes the advantages of the fast dynamic response of the conventional hysteresis current control and the reduced switching number of the SVM scheme. While the current errors go beyond the outer hysteresis band, a suitable space voltage vector is selected to obtain fast current response, which corresponding the vector of the current error differential is of the largest partial vector in reverse direction of current error vector. Otherwise, the low harmonic current control of SVM is selected to track the reference current and limit the current error within the specified hysteresis band. A set of space vectors including the zero vectors to reduce the number of switching is determined from the information of the middle current error. Then a proper space vector selected according to the inner current error for better current. Lastly, the validity and rapidity of the proposed method are confirmed by experimental tests.","PeriodicalId":166431,"journal":{"name":"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Improved hysteresis current control for active power filter\",\"authors\":\"X. Dianguo, Guo Jianjun, Liu Hankui, Gong Maozhong\",\"doi\":\"10.1109/ISIE.2003.1267929\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an improved hysteresis current control to enhance the performance of current tracking control for active power filter while reduce the number of switching. This control technique utilizes the advantages of the fast dynamic response of the conventional hysteresis current control and the reduced switching number of the SVM scheme. While the current errors go beyond the outer hysteresis band, a suitable space voltage vector is selected to obtain fast current response, which corresponding the vector of the current error differential is of the largest partial vector in reverse direction of current error vector. Otherwise, the low harmonic current control of SVM is selected to track the reference current and limit the current error within the specified hysteresis band. A set of space vectors including the zero vectors to reduce the number of switching is determined from the information of the middle current error. Then a proper space vector selected according to the inner current error for better current. Lastly, the validity and rapidity of the proposed method are confirmed by experimental tests.\",\"PeriodicalId\":166431,\"journal\":{\"name\":\"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)\",\"volume\":\"35 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.2003.1267929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.2003.1267929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

本文提出了一种改进的迟滞电流控制方法,在减少开关次数的同时,提高了有源电力滤波器的电流跟踪控制性能。该控制技术利用了传统迟滞电流控制动态响应快和支持向量机方案开关次数少的优点。当电流误差超出外滞回带时,选择合适的空间电压矢量以获得快速的电流响应,其对应的电流误差微分矢量是电流误差矢量反向的最大偏矢量。否则,选择支持向量机的低谐波电流控制,跟踪参考电流,将电流误差限制在规定的滞后带内。根据中间电流误差信息,确定了一组包含零矢量的空间矢量,以减少开关次数。然后根据内部电流误差选择合适的空间矢量以获得更好的电流。最后,通过实验验证了该方法的有效性和快速性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improved hysteresis current control for active power filter
This paper presents an improved hysteresis current control to enhance the performance of current tracking control for active power filter while reduce the number of switching. This control technique utilizes the advantages of the fast dynamic response of the conventional hysteresis current control and the reduced switching number of the SVM scheme. While the current errors go beyond the outer hysteresis band, a suitable space voltage vector is selected to obtain fast current response, which corresponding the vector of the current error differential is of the largest partial vector in reverse direction of current error vector. Otherwise, the low harmonic current control of SVM is selected to track the reference current and limit the current error within the specified hysteresis band. A set of space vectors including the zero vectors to reduce the number of switching is determined from the information of the middle current error. Then a proper space vector selected according to the inner current error for better current. Lastly, the validity and rapidity of the proposed method are confirmed by experimental tests.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Systematization of the project of the production system control Random weights search in compressed neural networks using overdetermined pseudoinverse Embedded system to recognize the heat power of a fuel gas and to classificate the quality of alcohol fuel Automatic P/PI speed control for industry servo drives using on-line spectrum analysis of torque command Boost half-bridge ballast with high power factor and auxiliary resonant branch
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1