固体介电材料内球形腔内局部放电行为随外加电压幅值的函数的测量和建模

H. Illias, George Chen, P. Lewin
{"title":"固体介电材料内球形腔内局部放电行为随外加电压幅值的函数的测量和建模","authors":"H. Illias, George Chen, P. Lewin","doi":"10.1109/ICHVE.2010.5640733","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) activity is always linked to insulation degradation, which can affect the performance of the insulation. Therefore, measurement of PD events can be used to assess the condition of the insulation. To assist the assessment of the performance of insulation materials, modelling of PD events can be used to attain a better understanding of this phenomenon. In this paper, a Finite Element Analysis (FEA) model for simulation of PD activity within a spherical cavity in a homogeneous dielectric material has been developed. The model has been used to study the influence of amplitude of the applied voltage on PD activity. Through comparisons of simulation and measurement results, some parameter values in the model are seen to be dependent on the applied voltage amplitude.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Measurement and modelling of partial discharge behaviour in a spherical cavity within a solid dielectric material as a function of applied voltage amplitude\",\"authors\":\"H. Illias, George Chen, P. Lewin\",\"doi\":\"10.1109/ICHVE.2010.5640733\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge (PD) activity is always linked to insulation degradation, which can affect the performance of the insulation. Therefore, measurement of PD events can be used to assess the condition of the insulation. To assist the assessment of the performance of insulation materials, modelling of PD events can be used to attain a better understanding of this phenomenon. In this paper, a Finite Element Analysis (FEA) model for simulation of PD activity within a spherical cavity in a homogeneous dielectric material has been developed. The model has been used to study the influence of amplitude of the applied voltage on PD activity. Through comparisons of simulation and measurement results, some parameter values in the model are seen to be dependent on the applied voltage amplitude.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640733\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640733","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

局部放电(PD)活动总是与绝缘劣化有关,而劣化会影响绝缘的性能。因此,对局部放电事件的测量可以用来评估绝缘的状况。为了帮助评估绝缘材料的性能,可以使用局部放电事件建模来更好地理解这一现象。本文建立了均匀介质中球形腔内PD活度的有限元分析模型。利用该模型研究了外加电压幅值对局部放电活性的影响。通过仿真和测量结果的比较,可以看出模型中的一些参数值依赖于外加电压幅值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement and modelling of partial discharge behaviour in a spherical cavity within a solid dielectric material as a function of applied voltage amplitude
Partial discharge (PD) activity is always linked to insulation degradation, which can affect the performance of the insulation. Therefore, measurement of PD events can be used to assess the condition of the insulation. To assist the assessment of the performance of insulation materials, modelling of PD events can be used to attain a better understanding of this phenomenon. In this paper, a Finite Element Analysis (FEA) model for simulation of PD activity within a spherical cavity in a homogeneous dielectric material has been developed. The model has been used to study the influence of amplitude of the applied voltage on PD activity. Through comparisons of simulation and measurement results, some parameter values in the model are seen to be dependent on the applied voltage amplitude.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Non-destructive test methods for hollow-core composite insulators Investigation of the effect of conductor temperature on AC power line corona Field characteristics and dielectric tests on an IGBT module plate Ultra wide band response of partial discharge test circuit The expert transformer monitoring system in substation structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1