{"title":"风电场电力存储管理方法的验证","authors":"C. Sourkounis, F. Richter, B. Ni","doi":"10.1109/CPE.2009.5156025","DOIUrl":null,"url":null,"abstract":"The stochastic fluctuating offer of wind energy limits the supply capacity in electrical grids by means of technical and economical reasons. A concept of dynamic conditioning was developed, which envisages support and management of the electrical grid respectively through compensation of active and reactive power with static converters and short time storage. Therefore short time fluctuation of the energy sources and changes of the load can be absorbed directly on location. By the use of dynamic storage systems an intermediate storage of the wind energy is done. This low order energy can thereby be converted into high order callable energy. Therefore the necessary storage capacity depends on the storage management method.","PeriodicalId":272748,"journal":{"name":"2009 Compatibility and Power Electronics","volume":"86 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Verification of management methods for power storage in wind parks\",\"authors\":\"C. Sourkounis, F. Richter, B. Ni\",\"doi\":\"10.1109/CPE.2009.5156025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The stochastic fluctuating offer of wind energy limits the supply capacity in electrical grids by means of technical and economical reasons. A concept of dynamic conditioning was developed, which envisages support and management of the electrical grid respectively through compensation of active and reactive power with static converters and short time storage. Therefore short time fluctuation of the energy sources and changes of the load can be absorbed directly on location. By the use of dynamic storage systems an intermediate storage of the wind energy is done. This low order energy can thereby be converted into high order callable energy. Therefore the necessary storage capacity depends on the storage management method.\",\"PeriodicalId\":272748,\"journal\":{\"name\":\"2009 Compatibility and Power Electronics\",\"volume\":\"86 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 Compatibility and Power Electronics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE.2009.5156025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Compatibility and Power Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2009.5156025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Verification of management methods for power storage in wind parks
The stochastic fluctuating offer of wind energy limits the supply capacity in electrical grids by means of technical and economical reasons. A concept of dynamic conditioning was developed, which envisages support and management of the electrical grid respectively through compensation of active and reactive power with static converters and short time storage. Therefore short time fluctuation of the energy sources and changes of the load can be absorbed directly on location. By the use of dynamic storage systems an intermediate storage of the wind energy is done. This low order energy can thereby be converted into high order callable energy. Therefore the necessary storage capacity depends on the storage management method.