S. Sreedharan, W. Ongsakul, J. G. Singh, K. Buayai, I. M. Wartana
{"title":"基于粒子群算法的FACTS控制器调优以实现风电在电力系统中的最大渗透","authors":"S. Sreedharan, W. Ongsakul, J. G. Singh, K. Buayai, I. M. Wartana","doi":"10.1109/ISET-INDIA.2011.6145404","DOIUrl":null,"url":null,"abstract":"In this paper, a new methodology has been proposed for attaining the maximum instantaneous wind penetration by the optimal placement and setting of Flexible AC Transmission System (FACTS) controllers. Multiple of single type of FACTS controller namely SVC have been used for achieving the maximum wind penetration. Particle Swarm Optimization (PSO) based algorithm has been developed to obtain the maximum instantaneous penetration by adjusting the grid parameters and FACTS controller settings. The developed algorithm has been tested on modified IEEE 14-bus test system. The results have shown the maximum instantaneous wind energy penetration limit in percentage, optimal setting of FACTS controllers and also maximum safe bus loading point explicitly beyond which system drives into instability.","PeriodicalId":265646,"journal":{"name":"ISGT2011-India","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"PSO based tuning of FACTS controllers for maximizing the wind energy penetration in power systems\",\"authors\":\"S. Sreedharan, W. Ongsakul, J. G. Singh, K. Buayai, I. M. Wartana\",\"doi\":\"10.1109/ISET-INDIA.2011.6145404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new methodology has been proposed for attaining the maximum instantaneous wind penetration by the optimal placement and setting of Flexible AC Transmission System (FACTS) controllers. Multiple of single type of FACTS controller namely SVC have been used for achieving the maximum wind penetration. Particle Swarm Optimization (PSO) based algorithm has been developed to obtain the maximum instantaneous penetration by adjusting the grid parameters and FACTS controller settings. The developed algorithm has been tested on modified IEEE 14-bus test system. The results have shown the maximum instantaneous wind energy penetration limit in percentage, optimal setting of FACTS controllers and also maximum safe bus loading point explicitly beyond which system drives into instability.\",\"PeriodicalId\":265646,\"journal\":{\"name\":\"ISGT2011-India\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISGT2011-India\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISET-INDIA.2011.6145404\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISGT2011-India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISET-INDIA.2011.6145404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
PSO based tuning of FACTS controllers for maximizing the wind energy penetration in power systems
In this paper, a new methodology has been proposed for attaining the maximum instantaneous wind penetration by the optimal placement and setting of Flexible AC Transmission System (FACTS) controllers. Multiple of single type of FACTS controller namely SVC have been used for achieving the maximum wind penetration. Particle Swarm Optimization (PSO) based algorithm has been developed to obtain the maximum instantaneous penetration by adjusting the grid parameters and FACTS controller settings. The developed algorithm has been tested on modified IEEE 14-bus test system. The results have shown the maximum instantaneous wind energy penetration limit in percentage, optimal setting of FACTS controllers and also maximum safe bus loading point explicitly beyond which system drives into instability.