一种用于能量回收负荷系统的宽范围输入电压的数字多模升压变换器

Chunfang Zheng, X. Xu, Bo Zhang, D. Qiu
{"title":"一种用于能量回收负荷系统的宽范围输入电压的数字多模升压变换器","authors":"Chunfang Zheng, X. Xu, Bo Zhang, D. Qiu","doi":"10.1109/PEAC.2014.7038087","DOIUrl":null,"url":null,"abstract":"This paper introduces a digital multi-mode boost converter with wide range of input voltage for an energy recycling load system. The boost converter is controlled digitally with constant off- time/constant frequency hybrid pulse width modulation (PWM) control. Constant off-time control is to avoid the limit cycle oscillation and gain a high gain when the input voltage is far less than the output voltage. Otherwise, constant frequency PWM is adopted. Finally, A 3.6kW DC/DC boost converter with twelve 300W channels in parallel was built for an energy recycling load system and the experimental results testify it to get high gain up to 49 and high efficiency up to about 98%.","PeriodicalId":309780,"journal":{"name":"2014 International Power Electronics and Application Conference and Exposition","volume":"188 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A digital multimode Boost converter with wide range of input voltage for an energy recycling load system\",\"authors\":\"Chunfang Zheng, X. Xu, Bo Zhang, D. Qiu\",\"doi\":\"10.1109/PEAC.2014.7038087\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper introduces a digital multi-mode boost converter with wide range of input voltage for an energy recycling load system. The boost converter is controlled digitally with constant off- time/constant frequency hybrid pulse width modulation (PWM) control. Constant off-time control is to avoid the limit cycle oscillation and gain a high gain when the input voltage is far less than the output voltage. Otherwise, constant frequency PWM is adopted. Finally, A 3.6kW DC/DC boost converter with twelve 300W channels in parallel was built for an energy recycling load system and the experimental results testify it to get high gain up to 49 and high efficiency up to about 98%.\",\"PeriodicalId\":309780,\"journal\":{\"name\":\"2014 International Power Electronics and Application Conference and Exposition\",\"volume\":\"188 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Power Electronics and Application Conference and Exposition\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEAC.2014.7038087\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Power Electronics and Application Conference and Exposition","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEAC.2014.7038087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种用于能量回收负荷系统的宽输入电压范围的数字多模升压变换器。升压变换器采用恒定关断时间/恒定频率混合脉宽调制(PWM)控制。恒离时控制是为了避免在输入电压远小于输出电压时出现极限环振荡,从而获得较高的增益。否则采用恒频PWM。最后,为能量回收负载系统构建了一个12个300W并联通道的3.6kW DC/DC升压变换器,实验结果表明,该变换器的高增益可达49,效率可达98%左右。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A digital multimode Boost converter with wide range of input voltage for an energy recycling load system
This paper introduces a digital multi-mode boost converter with wide range of input voltage for an energy recycling load system. The boost converter is controlled digitally with constant off- time/constant frequency hybrid pulse width modulation (PWM) control. Constant off-time control is to avoid the limit cycle oscillation and gain a high gain when the input voltage is far less than the output voltage. Otherwise, constant frequency PWM is adopted. Finally, A 3.6kW DC/DC boost converter with twelve 300W channels in parallel was built for an energy recycling load system and the experimental results testify it to get high gain up to 49 and high efficiency up to about 98%.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Harmonic stability assessment for multi-paralleled, grid-connected inverters An up-to-date review of large marine tidal current turbine technologies Optimal control for a self-reacting point absorber: A one-body equivalent model approach Comparison of direct-drive PM generators for tidal turbines Ocean wave energy extraction: Up-to-date technologies review and evaluation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1