GIS组件的临界性评估

M. Al-Suhaily, S. Meijer, J. Smit, P. Sibbald, J. Kanters, T. Tso
{"title":"GIS组件的临界性评估","authors":"M. Al-Suhaily, S. Meijer, J. Smit, P. Sibbald, J. Kanters, T. Tso","doi":"10.1109/ICHVE.2010.5640781","DOIUrl":null,"url":null,"abstract":"To ensure the high voltage gas insulated substations (GIS) reliability while maintaining maintenance costs, it is important to determine the criticality of GIS components and planning maintenance work based on the estimated criticality level. In this paper, the GIS primary system is broken down into indenture levels and subjected to the Failure Mode, Effect, and Criticality Analysis (FMECA) to estimate failures criticality for GIS components. The method is applied to one of the 380kV GIS installation in the Netherlands. The results have shown that circuit breakers have very high criticality level. Busducts and interconnecting parts, disconnectors, and SF6 bushings have high criticality level. And surge arresters have medium criticality.","PeriodicalId":287425,"journal":{"name":"2010 International Conference on High Voltage Engineering and Application","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Criticality assessment of GIS components\",\"authors\":\"M. Al-Suhaily, S. Meijer, J. Smit, P. Sibbald, J. Kanters, T. Tso\",\"doi\":\"10.1109/ICHVE.2010.5640781\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To ensure the high voltage gas insulated substations (GIS) reliability while maintaining maintenance costs, it is important to determine the criticality of GIS components and planning maintenance work based on the estimated criticality level. In this paper, the GIS primary system is broken down into indenture levels and subjected to the Failure Mode, Effect, and Criticality Analysis (FMECA) to estimate failures criticality for GIS components. The method is applied to one of the 380kV GIS installation in the Netherlands. The results have shown that circuit breakers have very high criticality level. Busducts and interconnecting parts, disconnectors, and SF6 bushings have high criticality level. And surge arresters have medium criticality.\",\"PeriodicalId\":287425,\"journal\":{\"name\":\"2010 International Conference on High Voltage Engineering and Application\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on High Voltage Engineering and Application\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE.2010.5640781\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on High Voltage Engineering and Application","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE.2010.5640781","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

为了保证高压气体绝缘变电站的可靠性,同时保证维护成本,确定GIS组件的临界水平并根据估计的临界水平规划维护工作是非常重要的。在本文中,GIS主要系统被分解为契约级别,并进行失效模式,影响和临界分析(FMECA)来估计GIS组件的失效临界性。该方法已应用于荷兰一个380kV GIS装置。结果表明,断路器具有很高的临界水平。导管和互连部件,隔离器和SF6套管具有高临界水平。避雷器有中等临界。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Criticality assessment of GIS components
To ensure the high voltage gas insulated substations (GIS) reliability while maintaining maintenance costs, it is important to determine the criticality of GIS components and planning maintenance work based on the estimated criticality level. In this paper, the GIS primary system is broken down into indenture levels and subjected to the Failure Mode, Effect, and Criticality Analysis (FMECA) to estimate failures criticality for GIS components. The method is applied to one of the 380kV GIS installation in the Netherlands. The results have shown that circuit breakers have very high criticality level. Busducts and interconnecting parts, disconnectors, and SF6 bushings have high criticality level. And surge arresters have medium criticality.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Non-destructive test methods for hollow-core composite insulators Investigation of the effect of conductor temperature on AC power line corona Field characteristics and dielectric tests on an IGBT module plate Ultra wide band response of partial discharge test circuit The expert transformer monitoring system in substation structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1