Y. Filatov, P. Korolev, A. V. Utushkina, A. Tsareva
{"title":"测量通道具有自动校正数据转换功能","authors":"Y. Filatov, P. Korolev, A. V. Utushkina, A. Tsareva","doi":"10.1109/EICONRUSNW.2015.7102258","DOIUrl":null,"url":null,"abstract":"In the report the technical solution for working off software and hardware the measuring channel is described, it is adapted to the size and speed of degradation of the metrological characteristics and thus makes it possible to ensure that the measuring class of accuracy as long as possible. The decision is based on the method of sample signals. The structure of the measuring channel of temperature with the four-wire communication line and possibility of switching of model resistance is used. The software allows to determine the systematic and random components of error and speeds their changes, to register the values of the errors and to take a statistically valid solution for the correction of the calibration curves.","PeriodicalId":268759,"journal":{"name":"2015 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Measuring channel with automatic correction data conversion\",\"authors\":\"Y. Filatov, P. Korolev, A. V. Utushkina, A. Tsareva\",\"doi\":\"10.1109/EICONRUSNW.2015.7102258\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the report the technical solution for working off software and hardware the measuring channel is described, it is adapted to the size and speed of degradation of the metrological characteristics and thus makes it possible to ensure that the measuring class of accuracy as long as possible. The decision is based on the method of sample signals. The structure of the measuring channel of temperature with the four-wire communication line and possibility of switching of model resistance is used. The software allows to determine the systematic and random components of error and speeds their changes, to register the values of the errors and to take a statistically valid solution for the correction of the calibration curves.\",\"PeriodicalId\":268759,\"journal\":{\"name\":\"2015 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EICONRUSNW.2015.7102258\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE NW Russia Young Researchers in Electrical and Electronic Engineering Conference (EIConRusNW)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EICONRUSNW.2015.7102258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Measuring channel with automatic correction data conversion
In the report the technical solution for working off software and hardware the measuring channel is described, it is adapted to the size and speed of degradation of the metrological characteristics and thus makes it possible to ensure that the measuring class of accuracy as long as possible. The decision is based on the method of sample signals. The structure of the measuring channel of temperature with the four-wire communication line and possibility of switching of model resistance is used. The software allows to determine the systematic and random components of error and speeds their changes, to register the values of the errors and to take a statistically valid solution for the correction of the calibration curves.