地方厂建2kva改进型正弦波太阳能逆变器的科学评价

A. O. S., Yusuf B. M, Ogunsakin O
{"title":"地方厂建2kva改进型正弦波太阳能逆变器的科学评价","authors":"A. O. S., Yusuf B. M, Ogunsakin O","doi":"10.54105/ijmm.d4057.033123","DOIUrl":null,"url":null,"abstract":"This paper presents scientific assessment of locally and factory built 2 kvA modified sine wave inverters. A data logger known as DENT ELITE PRO SP which was connected across the two solar inverters to collect relevant data. The captured data were harmonic distortion, voltage and current variation in the outputs of the solar inverters. An integrated circuit (IC) SG3524 was used to generate the necessary pulse needed to drive the MOSFET (3205IRF) to alternate the direct current (DC) supply. The output from the oscillator stage was amplified using power transistor MOSFET. The frequency at which circuit operate is determined with the oscillator stage. There were different points of interception for both current and voltage for both types of inverters over a stipulated period. The assessment summarily showed that the measurements for the factory made inverter range from 226.044V to 230.811V and these values were within the nominal voltage. However, for locally made inverter, the voltage measurements for the period under consideration were within 215.189V and 221.599V and this depicts a slight deviation from the nominal voltage values. The result showed that the factory built inverter is superior to the locally fabricated type and this implies that there should be improvement in the design of oscillating stage and the determination of the drain current of theMOSFET should be accurate.","PeriodicalId":170149,"journal":{"name":"Indian Journal of Microprocessors and Microcontroller","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Scientific Assessment of Locally and Factory Built 2 KVA Modified Sine Wave Solar Powered Inverters\",\"authors\":\"A. O. S., Yusuf B. M, Ogunsakin O\",\"doi\":\"10.54105/ijmm.d4057.033123\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents scientific assessment of locally and factory built 2 kvA modified sine wave inverters. A data logger known as DENT ELITE PRO SP which was connected across the two solar inverters to collect relevant data. The captured data were harmonic distortion, voltage and current variation in the outputs of the solar inverters. An integrated circuit (IC) SG3524 was used to generate the necessary pulse needed to drive the MOSFET (3205IRF) to alternate the direct current (DC) supply. The output from the oscillator stage was amplified using power transistor MOSFET. The frequency at which circuit operate is determined with the oscillator stage. There were different points of interception for both current and voltage for both types of inverters over a stipulated period. The assessment summarily showed that the measurements for the factory made inverter range from 226.044V to 230.811V and these values were within the nominal voltage. However, for locally made inverter, the voltage measurements for the period under consideration were within 215.189V and 221.599V and this depicts a slight deviation from the nominal voltage values. The result showed that the factory built inverter is superior to the locally fabricated type and this implies that there should be improvement in the design of oscillating stage and the determination of the drain current of theMOSFET should be accurate.\",\"PeriodicalId\":170149,\"journal\":{\"name\":\"Indian Journal of Microprocessors and Microcontroller\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indian Journal of Microprocessors and Microcontroller\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.54105/ijmm.d4057.033123\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Microprocessors and Microcontroller","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54105/ijmm.d4057.033123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文对国产和工厂生产的2kva改进型正弦波逆变器进行了科学评价。一个被称为DENT ELITE PRO SP的数据记录仪,连接在两个太阳能逆变器上收集相关数据。捕获的数据是太阳能逆变器输出的谐波失真、电压和电流变化。集成电路SG3524用于产生驱动MOSFET (3205IRF)交替直流(DC)电源所需的必要脉冲。振荡器级的输出使用功率晶体管MOSFET进行放大。电路工作的频率由振荡器级决定。在规定的时间内,两种类型的逆变器的电流和电压都有不同的拦截点。评估总结表明,工厂制造的逆变器的测量范围为226.044V至2308.11 v,这些值在标称电压范围内。然而,对于本地生产的逆变器,所考虑的期间的电压测量值在215.189V和221.599V之间,这与标称电压值略有偏差。结果表明,工厂制造的逆变器优于本地制造的逆变器,这意味着振荡级的设计应有所改进,并且mosfet的漏极电流的确定应准确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Scientific Assessment of Locally and Factory Built 2 KVA Modified Sine Wave Solar Powered Inverters
This paper presents scientific assessment of locally and factory built 2 kvA modified sine wave inverters. A data logger known as DENT ELITE PRO SP which was connected across the two solar inverters to collect relevant data. The captured data were harmonic distortion, voltage and current variation in the outputs of the solar inverters. An integrated circuit (IC) SG3524 was used to generate the necessary pulse needed to drive the MOSFET (3205IRF) to alternate the direct current (DC) supply. The output from the oscillator stage was amplified using power transistor MOSFET. The frequency at which circuit operate is determined with the oscillator stage. There were different points of interception for both current and voltage for both types of inverters over a stipulated period. The assessment summarily showed that the measurements for the factory made inverter range from 226.044V to 230.811V and these values were within the nominal voltage. However, for locally made inverter, the voltage measurements for the period under consideration were within 215.189V and 221.599V and this depicts a slight deviation from the nominal voltage values. The result showed that the factory built inverter is superior to the locally fabricated type and this implies that there should be improvement in the design of oscillating stage and the determination of the drain current of theMOSFET should be accurate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Scientific Assessment of Locally and Factory Built 2 KVA Modified Sine Wave Solar Powered Inverters ARM Microcontroller Based Wireless Industrial Automation System Automatic Water Tank Filling System with Water Level Indicator RFID-Based Digital Door Locking System Automatic Sprinkler System using Arduino
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1