EUV光谱范围内材料的高精度光学常数表征:从大型研究设施到实验室仪器

V. Soltwisch, S. Glabisch, A. Andrle, V. Philipsen, Q. Saadeh, S. Schröder, L. Lohr, R. Ciesielski, S. Brose
{"title":"EUV光谱范围内材料的高精度光学常数表征:从大型研究设施到实验室仪器","authors":"V. Soltwisch, S. Glabisch, A. Andrle, V. Philipsen, Q. Saadeh, S. Schröder, L. Lohr, R. Ciesielski, S. Brose","doi":"10.1117/12.2640176","DOIUrl":null,"url":null,"abstract":"Any modeling of an interaction between photons and matter is based on the optical parameters. The determination of these parameters, also called optical constants or refractive indices, is an indispensable component for the development of new optical elements such as mirrors, gratings, or lithography photomasks. Especially in the extreme ultraviolet (EUV) spectral region, existing databases for the refractive indices of many materials and compositions are inadequate or are a mixture of experimentally measured and calculated values from atomic scattering factors. Synchrotron radiation is of course ideally suited to verify such material parameters due to the tuneability of photon energy. However, due to the large number of possible compounds and alloys, the development of EUV laboratory reflectometers is essential to keep pace with the development of materials science and allow for inline or on-site quality control. Additionally, optical constants are also essential for EUV metrology techniques that aim to achieve dimensional reconstruction of nanopatterned structures with sub-nm resolution. For this purpose, we studied a TaTeN grating created on an EUV Mo/Si multilayer mirror, to mimic a novel absorber EUV photomask. We present here a first reconstruction comparison of these structures, measured by EUV scatterometry at the electron storage ring BESSYII and with a laboratory setup of a spectrally-resolved EUV reflectometer developed at RWTH Aachen University. Both approaches differ in several aspects reaching from setup size to spectral quality (brilliance, bandwidth and coherence) as well as the measured and simulated data.","PeriodicalId":287066,"journal":{"name":"European Mask and Lithography Conference","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"High-precision optical constant characterization of materials in the EUV spectral range: from large research facilities to laboratory-based instruments\",\"authors\":\"V. Soltwisch, S. Glabisch, A. Andrle, V. Philipsen, Q. Saadeh, S. Schröder, L. Lohr, R. Ciesielski, S. Brose\",\"doi\":\"10.1117/12.2640176\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Any modeling of an interaction between photons and matter is based on the optical parameters. The determination of these parameters, also called optical constants or refractive indices, is an indispensable component for the development of new optical elements such as mirrors, gratings, or lithography photomasks. Especially in the extreme ultraviolet (EUV) spectral region, existing databases for the refractive indices of many materials and compositions are inadequate or are a mixture of experimentally measured and calculated values from atomic scattering factors. Synchrotron radiation is of course ideally suited to verify such material parameters due to the tuneability of photon energy. However, due to the large number of possible compounds and alloys, the development of EUV laboratory reflectometers is essential to keep pace with the development of materials science and allow for inline or on-site quality control. Additionally, optical constants are also essential for EUV metrology techniques that aim to achieve dimensional reconstruction of nanopatterned structures with sub-nm resolution. For this purpose, we studied a TaTeN grating created on an EUV Mo/Si multilayer mirror, to mimic a novel absorber EUV photomask. We present here a first reconstruction comparison of these structures, measured by EUV scatterometry at the electron storage ring BESSYII and with a laboratory setup of a spectrally-resolved EUV reflectometer developed at RWTH Aachen University. Both approaches differ in several aspects reaching from setup size to spectral quality (brilliance, bandwidth and coherence) as well as the measured and simulated data.\",\"PeriodicalId\":287066,\"journal\":{\"name\":\"European Mask and Lithography Conference\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Mask and Lithography Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.2640176\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Mask and Lithography Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2640176","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

光子和物质之间相互作用的任何模型都是基于光学参数的。这些参数的测定,也称为光学常数或折射率,是开发新的光学元件(如反射镜、光栅或光刻光罩)不可或缺的组成部分。特别是在极紫外(EUV)光谱区域,现有的许多材料和成分的折射率数据库是不充分的,或者是实验测量值和原子散射因子计算值的混合。由于光子能量的可调性,同步辐射当然是验证这些材料参数的理想选择。然而,由于大量可能的化合物和合金,EUV实验室反射计的发展是必不可少的,以跟上材料科学的发展,并允许在线或现场质量控制。此外,光学常数对于旨在实现亚纳米分辨率的纳米图案结构的尺寸重建的EUV计量技术也是必不可少的。为此,我们研究了在EUV Mo/Si多层反射镜上创建的TaTeN光栅,以模拟一种新型的吸收EUV光掩膜。我们在这里提出了这些结构的第一次重建比较,通过电子存储环BESSYII的EUV散射测量和亚琛工业大学开发的光谱分辨EUV反射计的实验室装置进行测量。这两种方法在几个方面有所不同,从设置大小到光谱质量(亮度、带宽和相干性)以及测量和模拟数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High-precision optical constant characterization of materials in the EUV spectral range: from large research facilities to laboratory-based instruments
Any modeling of an interaction between photons and matter is based on the optical parameters. The determination of these parameters, also called optical constants or refractive indices, is an indispensable component for the development of new optical elements such as mirrors, gratings, or lithography photomasks. Especially in the extreme ultraviolet (EUV) spectral region, existing databases for the refractive indices of many materials and compositions are inadequate or are a mixture of experimentally measured and calculated values from atomic scattering factors. Synchrotron radiation is of course ideally suited to verify such material parameters due to the tuneability of photon energy. However, due to the large number of possible compounds and alloys, the development of EUV laboratory reflectometers is essential to keep pace with the development of materials science and allow for inline or on-site quality control. Additionally, optical constants are also essential for EUV metrology techniques that aim to achieve dimensional reconstruction of nanopatterned structures with sub-nm resolution. For this purpose, we studied a TaTeN grating created on an EUV Mo/Si multilayer mirror, to mimic a novel absorber EUV photomask. We present here a first reconstruction comparison of these structures, measured by EUV scatterometry at the electron storage ring BESSYII and with a laboratory setup of a spectrally-resolved EUV reflectometer developed at RWTH Aachen University. Both approaches differ in several aspects reaching from setup size to spectral quality (brilliance, bandwidth and coherence) as well as the measured and simulated data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Synergy between quantum computing and semiconductor technology New registration calibration strategies for MBMW tools by PROVE measurements OPC flow for non-conventional layouts: specific application to optical diffusers Lithographic performance of resist ma-N 1402 in an e-beam/i-line stepper intra-level mix and match approach High-precision optical constant characterization of materials in the EUV spectral range: from large research facilities to laboratory-based instruments
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1