{"title":"拥塞与可靠性的可分离性与独立性:理论与仿真","authors":"S. Blumsack, M. Ilić, L. Lave","doi":"10.1109/PES.2007.386036","DOIUrl":null,"url":null,"abstract":"One policy aim under electric-industry restructuring has been to replace the centralized utility planning process (integrated resource planning) with regional planning for network investments, and decentralized decision-making for merchant investments. Through specific policies such as encouraging market-based merchant transmission and the proposed establishment of National Interest Transmission Corridors under the Energy Policy Act of 2005, congestion and reliability have been treated as separable and independent system attributes. This paper brings together separate pieces of research in (S. Blumsack et al., 2006) to explore the proposition that transmission investments can be divided into those which relieve congestion and those which enhance system reliability. Using the DC power flow model with linear ATC, we derive some explicit necessary and sufficient analytical conditions under which the separability and independence assumptions hold. These include (i) the network is series-parallel; (ii) demand is completely price- inelastic; (iii) all customers value reliability identically; and (iv) the grid operator does not discriminate among customers when forced to physically ration consumption. Simulations using the IEEE 118-bus test system are presented which demonstrate the close dependence of reliability and congestion, except at very low levels of demand.","PeriodicalId":380613,"journal":{"name":"2007 IEEE Power Engineering Society General Meeting","volume":"112 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Separability and Independence of Congestion and Reliability: Theory and Simulations\",\"authors\":\"S. Blumsack, M. Ilić, L. Lave\",\"doi\":\"10.1109/PES.2007.386036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One policy aim under electric-industry restructuring has been to replace the centralized utility planning process (integrated resource planning) with regional planning for network investments, and decentralized decision-making for merchant investments. Through specific policies such as encouraging market-based merchant transmission and the proposed establishment of National Interest Transmission Corridors under the Energy Policy Act of 2005, congestion and reliability have been treated as separable and independent system attributes. This paper brings together separate pieces of research in (S. Blumsack et al., 2006) to explore the proposition that transmission investments can be divided into those which relieve congestion and those which enhance system reliability. Using the DC power flow model with linear ATC, we derive some explicit necessary and sufficient analytical conditions under which the separability and independence assumptions hold. These include (i) the network is series-parallel; (ii) demand is completely price- inelastic; (iii) all customers value reliability identically; and (iv) the grid operator does not discriminate among customers when forced to physically ration consumption. Simulations using the IEEE 118-bus test system are presented which demonstrate the close dependence of reliability and congestion, except at very low levels of demand.\",\"PeriodicalId\":380613,\"journal\":{\"name\":\"2007 IEEE Power Engineering Society General Meeting\",\"volume\":\"112 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Power Engineering Society General Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2007.386036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Power Engineering Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2007.386036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
电力工业重组的一个政策目标是用网络投资的区域规划和商业投资的分散决策取代集中的公用事业规划过程(综合资源规划)。通过鼓励以市场为基础的商业输电和2005年《能源政策法案》提出的建立国家利益输电走廊等具体政策,拥塞和可靠性已被视为可分离和独立的系统属性。本文汇集了(S. Blumsack et al., 2006)中的独立研究,以探索输电投资可以分为缓解拥塞和提高系统可靠性的命题。利用具有线性ATC的直流潮流模型,给出了可分性和独立性假设成立的几个明确的充分必要分析条件。这些包括(i)网络是串并联的;(ii)需求完全没有价格弹性;(iii)所有客户对可靠性的重视是一致的;(iv)电网运营商在被迫进行实际定量消费时,不会歧视客户。利用IEEE 118总线测试系统进行的仿真表明,除了在非常低的需求水平外,可靠性和拥塞密切相关。
Separability and Independence of Congestion and Reliability: Theory and Simulations
One policy aim under electric-industry restructuring has been to replace the centralized utility planning process (integrated resource planning) with regional planning for network investments, and decentralized decision-making for merchant investments. Through specific policies such as encouraging market-based merchant transmission and the proposed establishment of National Interest Transmission Corridors under the Energy Policy Act of 2005, congestion and reliability have been treated as separable and independent system attributes. This paper brings together separate pieces of research in (S. Blumsack et al., 2006) to explore the proposition that transmission investments can be divided into those which relieve congestion and those which enhance system reliability. Using the DC power flow model with linear ATC, we derive some explicit necessary and sufficient analytical conditions under which the separability and independence assumptions hold. These include (i) the network is series-parallel; (ii) demand is completely price- inelastic; (iii) all customers value reliability identically; and (iv) the grid operator does not discriminate among customers when forced to physically ration consumption. Simulations using the IEEE 118-bus test system are presented which demonstrate the close dependence of reliability and congestion, except at very low levels of demand.