一种用于核磁共振引导聚焦超声手术系统的病灶定位方法

Jiawei Gu, G. Shen
{"title":"一种用于核磁共振引导聚焦超声手术系统的病灶定位方法","authors":"Jiawei Gu, G. Shen","doi":"10.1109/BMEI.2015.7401523","DOIUrl":null,"url":null,"abstract":"MR-guided focused ultrasound surgery is a promising noninvasive thermotherapy. To achieve a rapider and more accurate treatment requires continuous attention. In this paper, a more precise method for focal positioning is proposed. The ultrasound transducer with phased array can shift the focal position within the target area. Several points with appropriate distance are selected to establish the mapping between ultrasound coordinates and MR coordinates. Then the target spots in a certain region can be aimed precisely. According to the experiment result, the error is limited to less than 1mm.","PeriodicalId":119361,"journal":{"name":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","volume":"70 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A focal positioning method used in the MR-guided focused ultrasound surgery system\",\"authors\":\"Jiawei Gu, G. Shen\",\"doi\":\"10.1109/BMEI.2015.7401523\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"MR-guided focused ultrasound surgery is a promising noninvasive thermotherapy. To achieve a rapider and more accurate treatment requires continuous attention. In this paper, a more precise method for focal positioning is proposed. The ultrasound transducer with phased array can shift the focal position within the target area. Several points with appropriate distance are selected to establish the mapping between ultrasound coordinates and MR coordinates. Then the target spots in a certain region can be aimed precisely. According to the experiment result, the error is limited to less than 1mm.\",\"PeriodicalId\":119361,\"journal\":{\"name\":\"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)\",\"volume\":\"70 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BMEI.2015.7401523\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 8th International Conference on Biomedical Engineering and Informatics (BMEI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEI.2015.7401523","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

磁共振引导聚焦超声手术是一种很有前途的无创热疗。为了实现更快速、更准确的治疗,需要持续的关注。本文提出了一种更精确的焦点定位方法。采用相控阵的超声换能器可以使目标区域内的焦点位置发生移位。选取距离合适的几个点,建立超声坐标与磁共振坐标的映射关系。这样就可以对某一区域的目标点进行精确瞄准。根据实验结果,误差控制在1mm以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A focal positioning method used in the MR-guided focused ultrasound surgery system
MR-guided focused ultrasound surgery is a promising noninvasive thermotherapy. To achieve a rapider and more accurate treatment requires continuous attention. In this paper, a more precise method for focal positioning is proposed. The ultrasound transducer with phased array can shift the focal position within the target area. Several points with appropriate distance are selected to establish the mapping between ultrasound coordinates and MR coordinates. Then the target spots in a certain region can be aimed precisely. According to the experiment result, the error is limited to less than 1mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ECG signal compressed sensing using the wavelet tree model Development of a quantifiable optical reader for lateral flow immunoassay A tightly secure multi-party-signature protocol in the plain model Breast mass detection with kernelized supervised hashing 3D reconstruction of human enamel Ex vivo using high frequency ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1