考虑分布式发电不确定性的中低压电力系统谐波分配

J. David, V. Gosbell, D. Robinson, S. Perera, S. Elphick
{"title":"考虑分布式发电不确定性的中低压电力系统谐波分配","authors":"J. David, V. Gosbell, D. Robinson, S. Perera, S. Elphick","doi":"10.1109/ICHQP46026.2020.9177895","DOIUrl":null,"url":null,"abstract":"A key component to management of harmonic voltage levels in MV and LV distribution systems is the allocation of harmonic emissions to MV and LV customers. The principals of harmonic emission allocations outlined in IEC Technical Report 61000-3-6 are relatively straight forward to apply when both the capacity of the network and the extent of all future load connections are known. However, allocations are made more complex when distributed generation, typically power electronic based, are added to the mix of customer connections. This added complexity is due to distributed generation potentially impacting the hosting capacity of the network, i.e. enabling more customer connections, and the uncertainty for network planners in quantifying the likelihood of future distributed generation connections, given the prolific growth of renewables. This paper introduces a tapered probabilistic approach for network planners to undertake harmonic emission allocations for MV and LV networks which are likely to host significant levels of renewable based distribution generation. The method is demonstrated using a simplified network model.","PeriodicalId":436720,"journal":{"name":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Harmonic Allocation Allowing for Uncertainty of Distributed Generation in MV/LV Power Systems\",\"authors\":\"J. David, V. Gosbell, D. Robinson, S. Perera, S. Elphick\",\"doi\":\"10.1109/ICHQP46026.2020.9177895\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A key component to management of harmonic voltage levels in MV and LV distribution systems is the allocation of harmonic emissions to MV and LV customers. The principals of harmonic emission allocations outlined in IEC Technical Report 61000-3-6 are relatively straight forward to apply when both the capacity of the network and the extent of all future load connections are known. However, allocations are made more complex when distributed generation, typically power electronic based, are added to the mix of customer connections. This added complexity is due to distributed generation potentially impacting the hosting capacity of the network, i.e. enabling more customer connections, and the uncertainty for network planners in quantifying the likelihood of future distributed generation connections, given the prolific growth of renewables. This paper introduces a tapered probabilistic approach for network planners to undertake harmonic emission allocations for MV and LV networks which are likely to host significant levels of renewable based distribution generation. The method is demonstrated using a simplified network model.\",\"PeriodicalId\":436720,\"journal\":{\"name\":\"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"31 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP46026.2020.9177895\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 19th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP46026.2020.9177895","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

管理中低压配电系统谐波电压水平的一个关键组成部分是分配给中低压用户的谐波排放。IEC技术报告61000-3-6中概述的谐波发射分配原则在网络容量和所有未来负载连接的范围都已知的情况下相对直接地适用。然而,当分布式发电(通常是基于电力电子)被添加到客户连接的组合中时,分配变得更加复杂。这种增加的复杂性是由于分布式发电可能会影响网络的承载能力,即实现更多的客户连接,以及考虑到可再生能源的快速增长,网络规划者在量化未来分布式发电连接的可能性时存在不确定性。本文介绍了一种锥形概率方法,用于网络规划者对中压和低压网络进行谐波排放分配,这些网络可能承载大量基于可再生能源的配电发电。用一个简化的网络模型对该方法进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Harmonic Allocation Allowing for Uncertainty of Distributed Generation in MV/LV Power Systems
A key component to management of harmonic voltage levels in MV and LV distribution systems is the allocation of harmonic emissions to MV and LV customers. The principals of harmonic emission allocations outlined in IEC Technical Report 61000-3-6 are relatively straight forward to apply when both the capacity of the network and the extent of all future load connections are known. However, allocations are made more complex when distributed generation, typically power electronic based, are added to the mix of customer connections. This added complexity is due to distributed generation potentially impacting the hosting capacity of the network, i.e. enabling more customer connections, and the uncertainty for network planners in quantifying the likelihood of future distributed generation connections, given the prolific growth of renewables. This paper introduces a tapered probabilistic approach for network planners to undertake harmonic emission allocations for MV and LV networks which are likely to host significant levels of renewable based distribution generation. The method is demonstrated using a simplified network model.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Important Considerations in Development of PV Inverter Models for High Frequency Emission (Supraharmonic) Studies Transient response of single-phase photovoltaic inverters to step changes in supply voltage distortion ICHQP 2020 Title Page Current Practice on Power Quality Legislation within European Transmission Systems – Results from Horizon 2020 Project MIGRATE Evaluation of Jacobian used in Simulation of Nonlinear Circuits in the Modified Harmonic Domain
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1